background image

 

 

 

 

 

 

 
 

 

               SENS Limited Warranty Policy 

 

 

 

What is covered: 

This warranty covers any defect in material and workmanship on battery chargers manufactured 
by Stored Energy Systems, a Colorado Limited  

 

Liability Company (SENS).   
 

 

What this warranty does not cover: 

This warranty does not cover damages, defects or failures of your equipment resulting from 
shipping damage, accidents, installation errors, unauthorized adjustment or repair, unauthorized 
third-party service, failure to follow instructions, misuse, fire, flood, acts of persons not in our 
control, and acts of God.   
 

For how long: 

Two years from date of shipment. 

 

 

What we will do: 

If your battery charger is defective within two years of date of shipment, we will repair it or, at 
our option, replace it at no charge to you.   
 
If we choose to replace your charger, we may replace it with a new or refurbished one of the 
same or similar design.  The repair or replacement will be warranted for the remainder of the 
original two-year warranty period.  If we determine that your charger cannot be repaired or 
replaced, we will refund its purchase price to you. 
 

What we ask you to do: 

First contact SENS service department to obtain warranty service  

instructions.  To obtain 

warranty service the product must be returned, freight prepaid, to the factory under a Return 
Merchandise Authorization  

(RMA) number provided by SENS.  If, in SENS’ opinion, the 

problem can be rectified in the field, SENS may elect to ship replacement parts for customer 
installation instead of having the product returned to the factory.   
 

 

Limitation: 

This warranty is limited to defects in material or workmanship of the product.  It does not cover 
loss of time, inconvenience, property damage or any consequential damages.  Repair, 
replacement or refund of the purchase price of the equipment is your exclusive remedy.   
 
Form.135-1 

Summary of Contents for F3 SERIES

Page 1: ...106902 Date 11 20 15 1840 Industrial Circle Longmont CO 80501 Fax 303 678 7504 Tel 303 678 7500 Email service sensusa com Web www sens usa com Installation or Service problems Call SENS at 800 742 232...

Page 2: ...rdance with all local codes Do not expose charger to rain or snow Do not disassemble charger return to factory when service or repair is required Incorrect assembly may result in a risk of electric sh...

Page 3: ...tage to decay and reset the shutdown 6 If the battery is being over or undercharged check whether the output voltage settings have been tampered with The pots should be covered with either white adhes...

Page 4: ...mounting dimensions Relay Rack Mounting The charger is shipped on its back with the mounting flanges in the wall mount position Place the charger in a vertical position then unbolt and reverse the mo...

Page 5: ...AC requirement of your charger The input voltage and frequency are marked on the charger s front panel Maximum current consumption will be approximately 75 to 80 of the breaker s rating Typical effic...

Page 6: ...none none Ground fault LED none none Ground fault LED none none Ground fault or Form C contact none Summary of above Summary of above Form C contact Connect to the charger s Form C contacts according...

Page 7: ...s OK if the battery voltage is different from the nominal value by a few percent If the battery voltage is more than 10 different from the rated voltage of the charger recheck your connections BEFORE...

Page 8: ...on the charger will start in the boost mode and stay there until current demanded drops below about 50 of the charger s rated current When current demand increases to about 70 of the charger s rated o...

Page 9: ...he charger has malfunctioned LOW DC Indicates that DC voltage has dropped to approximately 8 5 below nominal battery voltage e g 22 volts for a 24 volt system Probable causes a The AC power has failed...

Page 10: ...ion of high voltage shutdown GROUND optional This is a ground fault alarm If either the charger s positive or negative is connected to ground even through a high resistance path this alarm will activa...

Page 11: ...2 21 High DC shutdown 15 19 30 39 40 52 60 78 151 95 212 73 303 89 Chargers set for flooded lead acid battery 12 volt 24 volt 32 volt 48 volt 120 volt 168 volts 240 volt Float voltage 13 32 26 64 35 5...

Page 12: ...d except when either charger is in BOOST mode whether activated manually or via the AUTO BOOST system or if either charger is operating in current limit Chargers will share the load within 10 of each...

Page 13: ...g diode short Check all power devices for shorts Replace shorted device s DC fuse blows or DC breaker trips Control board failure Replace with known good board Replace board send bad board to SENS for...

Page 14: ...lter capacitor Disconnect capacitors one at a time and check for change in output voltage Replace capacitor that corrected output voltage when removed Alarms or indicators not functioning Alarm displa...

Page 15: ...te a defective SCR Test 5 Due to the modest cost of the control circuit we recommend that the entire unit be replaced rather than attempting to repair it If the troubleshooting guide has not revealed...

Page 16: ...F3 Series Charger Manual 16...

Page 17: ...TOBOOST returns charger to f loat v oltage 100 charger output current 50 to 75 of charger current limit Amps Volts Charger output current Battery voltage NOTE Zero current f low 0 Time When the charge...

Page 18: ......

Page 19: ......

Page 20: ...it with a new or refurbished one of the same or similar design The repair or replacement will be warranted for the remainder of the original two year warranty period If we determine that your charger...

Reviews: