![background image](http://html1.mh-extra.com/html/sennheiser/net-1/net-1_instructions-for-use-manual_1240130024.webp)
24
Operation with 3000/5000 series systems
Transferring frequencies to receivers when a PC is connected
For 3000/5000 series systems, the frequency scan and the frequency
assignment can only be performed using the “Wireless Systems Manager” PC
software. For information on how to configure the EM 3532 twin receiver via
a PC, please refer to the instructions for use of the “Wireless Systems
Manager” software.
The “Wireless Systems Manager” software provides a database with preset
intermodulation-free frequencies to be used for configuring the EM 3532
twin receiver.
Transferring frequencies to the transmitters without a frequency scan
The infrared interface of the SK 5212 portable transmitter is located below
the display in the black frame. The infrared interfaces of the SKM 5200 hand-
held transmitters and the SKP 3000 plug-on transmitters are located inside
the display window of the transmitter.
Note:
Strong extraneous light may interfere with data transfer via the infrared
interface. Therefore, position the NET 1 so as to avoid interference from
extraneous light.
왘
Switch on the transmitter as described in the instructions for use of the
transmitter.
왘
Place the transmitter in front of the infrared interface
. The distance
between the infrared interface of the NET 1 and the infrared interface of
the transmitter must not exceed 10 cm.
왘
On the NET 1, press the channel button
corresponding to the receiver
whose frequency you want to transfer.
The green “CHANNEL” LED
corresponding to the receiver flashes rapidly,
indicating that data is being transferred to the transmitter. At the same
time, the yellow “DATA LINK” LED
flashes slowly and the infrared
interface
is permanently backlit in blue.
When the frequency transfer is completed, the green “CHANNEL” LED
and the “DATA LINK” LED
light up permanently.
If the frequency transfer was unsuccessful, the “ERROR” LED
flashes
rapidly for approx. 3 seconds and the green “CHANNEL” LED
flashes
permanently:
왘
Reposition the transmitter in front of the infrared interface until the
frequency transfer is successfully completed
or
왘
select another transmitter from the matching frequency range and place
this transmitter in front of the infrared interface.
SK 5212
SKP 3000
SKM 5200
10 cm
<