CARRIER ID CONFIGURATION
↕
LATITUDE: +44.5550
>TRANSMIT LONGITUDE: ENABLE
LONGITUDE:-109.9998
TRANSMIT TELEPHONE: ENABLE
CARRIER ID CONFIGURATION ↕
TRANSMIT TELEPHONE: ENABLED
>TEL: +659884334433
TRANSMIT USER DATA: ENABLED
USER: UPLINK KCCC 1 SD
-
Entered Value
Description:
When enabled, the entered latitude value is added to the Information Field of the CID
transmission. Enter values 0 to 90 with up to 3 decimal places. Enter positive values for northern
hemisphere and negative values for the southern hemisphere. When disabled, the latitude value
is not transmitted in the CID.
Longitude
: Provides entry of a longitude decimal value
to the CID information field.
-
Enable/
Disable
-
Entered Value
Description:
When enabled, the entered longitude value
is added to the Information Field of the CID. Enter values 0 to 180 with up to 4 decimal places.
Enter positive values for eastern hemisphere and negative values for the western hemisphere.
Wen disabled, the longitude value is not transmitted in the CID.
Telephone:
Provides an entry of a contact phone
number with an extension number to the CID
Information Field.
-
Enable
/Disable
-
Entered Value
Description:
When enabled, the entered phone number is added to the Information Field of the
CID. You may enter up to 18 digits or a total of 17 digits if an extension number is entered in the
ext. field. When disabled, the telephone number is not transmitted in the CID.
User Data
: Provides an entry of up to 24 characters for including a message in the CID
Information Field.
-
Enable/
Disabled
-
Text Entry Field
Description:
When enabled, the user data or entered characters are added into the CID
Information Field. Up to 24 characters may be entered and transmitted as user data. When
disabled, the user data is not transmitted in the CID.
Note:
When a CID carrier is enabled and added to the transmission or modulated RF output of
the SMD 989 it slightly degrades the MER performance of the RF transmission.
Entering CID Values:
The latitude, longitude, telephone and user data Carrier ID Configuration
fields are all fields which permit user data selection/entry. Press the UP or DOWN arrow front
panel pushbutton to position the arrow in front of the selection row in the menu. Press the front
panel ENTER button to enter. A field is highlighted as the selected digit or character. Press the
UP or DOWN front panel buttons to increment through available values or characters in that field.
Press the LEFT or RIGHT arrow buttons to move to the next field and repeat until the desire