background image

EN - 6

WIRELESS SENSOR SIGNAL RECEIVING

1.  In normal mode, press 

[SENSOR] 

key once to start receiving the sensor signal of 

current on displaying channel. The signal icon will flash.

 

For example, when 

CH 2 

is displayed, pressing 

[SENSOR] 

key will start receive for 

CH 2 

only.

2.  The signal icon will flash until the reception succeeded. If no signal is received within 

5 minutes the icon will disappear.

Receiving wireless signal after manual reset or the 

[SENSOR] 

key is pressed

  

 

 D/M

 M/D

 M/ 

 D

 

When waiting for signals, “--” will display in the readings field

  

 

 D/M

 M/D

 M/ 

 D

 

Good wireless sensor signal

  

 

 D/M

 M/D

 M/ 

 D

 

1.  If the signal for the current channel has discontinued 

and does not recover within 1 hour, the signal icon will 

disappear.

 

The temperature and humidity will display “

Er

” for the 

corresponding channel.

2.  If the signal does not recover within 48 hours, the “

Er

” 

display will become permanent you need to replace 

the batteries of “

Er

” channel’s sensors and then press 

[SENSOR] 

key to pair up the sensors of each “

Er

” channels 

again.

 NOTE:

After replacing the batteries of the wireless sensor or the unit fails to receive wireless 

sensor signal of a specified channel. During the failed channel is displaying, press 

[SENSOR] 

key to manually receive that sensor signal again.

VIEW CHANNEL OF MULTIPLE WIRELESS SENSORS

This main unit can support up to 8 additional wireless sensor(s).

1.  If you buy the additional wireless sensor(s) and paired with the main unit. Then, you 

can press 

[CH / +] 

key to switch the display between 

CH 1~8

.

2.  In normal mode, press and hold 

[CH / +] 

key for 2 seconds to enter auto-cycle mode, 

after a bi sounds, it will alternately displays the channels at 4 second intervals.

3.  During auto-cycle mode, press 

[CH / +] 

key once to stop auto-cycle and display the 

current channel.

4.  Using auto-cycle mode will only display the communicated channels. For example, 

when 

CH 1 

and 

have received the signal from the corresponding sensor, press and 

hold 

[CH / +] 

key for 2 seconds will only toggle the readings of 

CH 1 

and 

6

. Other 

channels will be neglected.

  

 

 D/M

 M/D

 M/ 

 D

 

Summary of Contents for SWS 7300

Page 1: ...Á STANICE S BAREVNÝM DISPLEJEM A BEZDRÁTOVÝM SNÍMAČEM NÁVOD NA OBSLUHU METEOROLOGICKÁ STANICA S FAREBNÝM DISPLEJOM A BEZDRÔTOVÝM SNÍMAČOM HASZNÁLATI ÚTMUTATÓ METEOROLÓGIAI ÁLLOMÁS SZÍNES KEPERNYŐVEL ÉS VEZETÉK NÉLKÜLI ÉRZÉKELŐVEL INSTRUKCJA OBSŁUGI STACJA POGODOWA Z KOLOROWYM WYŚWIETLACZEM I CZUJNIKIEM BEZPRZEWODOWYM ...

Page 2: ... symbol represents a warning To ensure safe use always adhere to the instructions described In this documentation This symbol is followed by a user s tip OVERVIEW MAIN UNIT 1 2 3 4 5 10 11 12 17 18 14 13 19 16 15 8 6 7 9 1 ALARM SNOOZE key 2 LCD display 3 MEM key 4 ALARM key 5 ALERT key 6 CH key 7 INDEX key 8 HISTORY key 9 Table stand 10 Wall mount hole 11 C F key 12 12 24 key 13 BARO key 14 SENSO...

Page 3: ...ather index moon phase section 1 3 2 4 5 6 1 4 5 6 3 2 WIRELESS HYGRO THERMO SENSOR WITH RCC RECEIVE FUNCTION 1 3 2 4 5 6 1 4 5 6 3 2 1 Transmission status LED 2 RCC receive key Press for RCC receiving 3 RESET key 4 Wall mounting holder 5 CHANNEL slide switch Assign the sensor to Channel 1 2 3 4 5 6 7 or 8 6 Battery compartment Accommodates 2 AA size batteries ...

Page 4: ...n cause severe internal burns in just 2 hours and can lead to death Keep new and used batteries away from children If the battery compartment does not close securely stop using the product and keep it away from children If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical attention CAUTION Risk of explosion if the battery is replaced by an i...

Page 5: ...battery compartment 3 Close the battery door Power up console 1 Plug the power adapter USB plug to power up the main unit 2 Once the main unit power up it will enter normal time mode USB cable TABLE STAND INSTALLATION The unit is designed for desktop or wall mount for easy viewing follow the steps below to hook the table stand on the botton of the console Step 1 Step 2 NOTE If no display appears o...

Page 6: ...s sensors and then press SENSOR key to pair up the sensors of each Er channels again NOTE After replacing the batteries of the wireless sensor or the unit fails to receive wireless sensor signal of a specified channel During the failed channel is displaying press SENSOR key to manually receive that sensor signal again VIEW CHANNEL OF MULTIPLE WIRELESS SENSORS This main unit can support up to 8 add...

Page 7: ... into 2 types No RCC signal received Received RCC signal NOTE Every day the wireless sensor will automatically search for the time signal at 2 00 and 17 00 Always place the unit away from interfering sources such as TV set computer etc Avoid placing the unit on or next to metal plate Closed area such as airport basement tower block or factory is not recommended Do not start reception on a moving a...

Page 8: ...fset weekday language RCC ON OFF DST AUTO OFF 5 When you complete the setting press CLOCK SET key or leave the unit for 60 seconds to return to normal mode NOTE DST AUTO OFF setting only available when RCC function is ON 12 24H setting D M M D M D Hour Minute Second setting D M M D M D Year setting D M M D M D Month Day setting D M M D M D D M M D M D Month day setting D M M D M D Time offset sett...

Page 9: ... alarm time as described in the above section 2 Or press ALARM key to display the alarm time press it again to turn on alarm function with the alarm icon displayed on the LCD 3 When clock reach the alarm time alarm sound will start Where it can be stopped by following operation a Auto stop after 2 minutes alarming if without any operation and the alarm will activate again in the next day b By pres...

Page 10: ...changes in the forthcoming few minutes Arrows indicate a rising steady or falling trend Arrow indicator Arrow indicator Too cold Too hot Arrow indicator Too cold Too hot Arrow indicator Too cold Too hot Trend Rising Steady Falling COMFORT INDICATION The comfort indication is a pictorial indication based on indoor air temperature and humidity in an attempt to determine comfort level Arrow indicator...

Page 11: ...utdoor temperature is below 3 C 26 F the SNOWY weather indicator will be displayed on the LCD BAROMETRIC ATMOSPHERIC PRESSURE TO SELECT THE PRESSURE DISPLAY MODE 1 Press and hold the BARO key for 2 seconds to enter select model 2 Press CH key or MEM key to select between abs the absolute atmospheric pressure of your location rel the relative atmospheric pressure based on the sea 3 In abs mode pres...

Page 12: ... on the sea level but it will change with the absolute atmosphere pressure changes after operating the clock for 1 hour HEAT INDEX DEW POINT TO VIEW HEAT INDEX Press the INDEX key repeatedly to show HEAT INDEX value NOTE Heat index is only calculated when temperature is 27 C 80 F or above and based solely from the temperature and humidity measured from the outdoor wireless sensors TO VIEW DEW POIN...

Page 13: ...y maximum baro reading minimum baro reading 3 When the MAX MIN records are shown the display will return to normal mode after leaving the unit for 6 seconds 4 To erase the MAX MIN records of indoor or current channel press and hold MEM key for 2 seconds when the unit is displaying MAX MIN records ALERT SETTING AND DISPLAY The unit can setup temperature HI LO alert for indoor and up to 8 outdoor ch...

Page 14: ... ALERT key to stop the alarm sound If you ignore the alarm it will stop after 2 minutes When auto cycle mode if any alarm is triggered the display will switch to the regarding channel You can press ALARM SNOOZE ALARM or ALERT key or leave the unit for 2 minutes to stop the alarm The display will return to auto cycle mode afterwards MOON PHASE The main unit can show the northern hemisphere moon pha...

Page 15: ...battery When CH 1 is displayed the icon will show NOTE The batteries in main unit are only for backup purpose the battery life cannot maintain for long time usage BACKLIGHT The main unit backlight can be adjust using the HI LO AUTO sliding switch to select the appropriate brightness Slide to the HI position for the brighter backlight Slide to the LO position for the dimmer backlight Slide to the A...

Page 16: ...ark commercial registration number and address HUA XU ELECTRONICS FACTORY No 1 Shi Tang Bei Street 2 Shi Jie Town Dong Guan City Guang Dong P R China Model identifier HX075 0501000 AG 001 Input voltage AC100 240V Input AC frequency 50 60Hz Output voltage DC5 0V Output current 1 0A Output power 5 0W Average active efficiency 64 93 No load power consumption 0 10W Wireless sensor Dimensions W H D 61 ...

Page 17: ...te Please ask your local authorities or the nearest waste collection centre for further details The improper disposal of this type of waste may fall subject to national regulations for fines For business entities in the European Union If you wish to dispose of an electrical or electronic device request the necessary information from your seller or supplier Disposal in other countries outside the E...

Page 18: ...stallation This warranty is void especially if apply as follows Defects which were put on sale Wear out or damage caused by common use The product was damaged by unprofessional or wrong installation used in contrary to the applicable instruction manual used in contrary to legal enactment and common process of use or used for another purpose which has been designed for The product was damaged by un...

Page 19: ......

Reviews: