Wall Mounted Split Air Conditioner
SAC 1811CH / SAC 2411CH
EN
EN-25
02/2015
Copyright © 2015, Fast ČR, a.s.
INSTALLING THE INDOOR UNIT
Installing the mounting plate
K
Model 2000 3500 W
(Model 7000 12000 BTU/h)
44 0 m m
2 3
0 m
m
44 0 m m
20 m m
90 m m
Model 5100 W
Model 6000-7000 W
Model (21000-24000 BTU/h)
90 m m
70 m
m
80 m m
12 m m
1 2
m m
(Model 18000 BTU/h)
Attach a string to the
middle hole
min. 250 mm
from the ceiling
min. 155 mm
from an adjacent wall
Hole for the pipe
Centre of the hole
(Ø 65 mm)
Plumb bob
min. 105 mm
from an adjacent wall
Centre of the hole
(Ø 65 mm)
Note:
Holes marked with a full arrow must be properly secured so that the mounting plate does not
move.
When using expansion bolts, standard holes should be drilled (11 x 20 or 11 x 26) and their
distances must be adhered to – min. 450 mm.
The mounting plate must be installed on a load bearing part of the wall (pole, etc.).
The actual design of the mounting plate may differ depending on the model of the air
conditioning device. The pictures used in this user‘s manual are for illustration purposes only.
ELECTRICAL CONNECTION OF THE INDOOR UNIT
L
1
2
3
1
Terminal of the indoor unit
2
Screw
3
Connecting cable