EN-24
EN
Wall Mounted Split Air Conditioner
SAC 1811CH / SAC 2411CH
02/2015
Copyright © 2015, Fast ČR, a.s.
ILLUSTRATION OF THE INSTALLATION
Indoor unit
I
min. 105 mm
min. 155 mm
min. 250 mm
Note
:
The actual design of the mounting plate may differ
depending on the model of the air conditioning device.
Marking out the installation
location using the mounting
plate of the indoor unit.
The connecting pipe may
lead from the rear, the
right, the left or below the
rear side.
right side
front side
bottom
rear
left rear side
left
side
Note:
The drain hose must
not be elevated too
high.
When installing the pipe
on a thin board or on
a wall from metal mesh it is
necessary to place a wooded
board between the wall
and the pipe and to wrap
the pipe with 7
–
8 layers of
insulating tape.
The connecting pipe must
be wrapped in a thermally
impervious material.
Soft plastic thermally
impervious material,
thickness 8 mm.
Outdoor unit
J
min. 500 mm
min. 300 mm
min. 500 mm
min. 500 mm
min. 300 mm