background image

3

INTRODUCTION

Congratulations on the purchase of your new SENCO ® Air Compressor! You can be assured your SENCO Air
Compressor was constructed with the highest level of precision and accuracy. Each component has been rigorously
tested by technicians to ensure the quality, endurance and performance of this air compressor.

This operator’s manual was compiled for your benefit. By reading and following the simple safety, installation and
operation, maintenance and troubleshooting steps described in this manual, you will receive years of troublefree
operation from your new SENCO ® Air Compressor. The contents of this manual are based on the latest product
information available at the time of publication. The manufacturer reserves the right to make changes in price,
color, materials equipment, specifications or models at any time without notice.

SAFETY ALERT!

A ”

DANGER, WARNING or CAUTION

” safety warning will be surrounded by a ”SAFETY ALERT BOX”.

This box is used to designate and emphasize Safety Warnings that must be followed when operating this
air compressor. Accompanying the safety warnings are “Signal Words” which designate the degree or
level of hazard seriousness. The “Signal Words” used in this manual are as follows:

DANGER:

Indicates an imminently hazardous situation which, if not avoided,
WILL result in death or serious injury.

WARNING:

Indicates a potentially hazardous situation which, if not avoided,
COULD result in death or serious injury.

CAUTION:

Indicates a potentially hazardous situation which, if not avoided
MAY result in minor or moderate injury or damage to the air
compressor.

The symbols set to the left of this paragraph are “Safety Alert Symbols”.
These symbols are used to call attention to items or procedures that could
be dangerous to you or other persons using this equipment.

ALWAYS PROVIDE A COPY OF THIS MANUAL TO ANYONE USING THIS EQUIPMENT. READ ALL
INSTRUCTIONS IN THIS MANUAL AND ANY INSTRUCTIONS SUPPLIED BY MANUFACTURERS OF
SUPPORTING EQUIPMENT BEFORE OPERATING THIS AIR COMPRESSOR AND ESPECIALLY POINT OUT
THE “SAFETY WARNINGS” TO PREVENT THE POSSIBILITY OF PERSONAL INJURY TO THE OPERATOR.

INSPECTION

Unbox the air compressor and write in the serial number in the space provided below. Inspect for signs of obvious
or concealed freight damage. Be sure that all damaged parts are replaced and any mechanical problems are
corrected prior to the operation of the air compressor.

SERIAL NUMBER__________________________________________

If you have Questions or Comments call SENCO’s toll-free Action-line: 1-800-543-4596 or, e-mail:
[email protected]

Please have the following information available for all service calls:

1. Model Number
2. Serial Number
3. Date and Place of Purchase

Senco® Corporation 8485 Broadwell Road, Cincinnati, OH 45244

Summary of Contents for PC1005

Page 1: ...the safe use of this compressor are included in this manual PC 1005 Electric Air Compressor Questions Comments call SENCO S toll free Action line 1 888 222 8144 or e mail toolprof senco com Code 19773...

Page 2: ...5 BREATHING 6 BURNS 6 FLYING OBJECTS 6 MOVING PARTS 7 NEGLIGENCE 7 AIR COMPRESSOR DAMAGE 7 COMPRESSOR FEATURES 8 PREPARATION 10 INITIAL SET UP 10 LOCATION 10 ELECTRICAL 10 OPERATION 11 PRE START CHECK...

Page 3: ...ot avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CAUTION Indicates a potentially hazar...

Page 4: ...electrical cords to lay in water or in such a position where water could come in contact with them Do not touch plug with wet hands Do not pull on the electrical cord to disconnect from the outlet Nev...

Page 5: ...ble dust gases or other combustible materials If spraying flammable material locate the air compressor at least 20 feet away from the spray area An additional hose may be required Never place objects...

Page 6: ...from the air compressor either directly or from a breathing device connected to the air compressor Operate air compressor only in a well ventilated area Follow all safety instructions provided with t...

Page 7: ...restart at any time Do not operate without protective covers guards Replace damaged covers guards before using the air compressor Never allow children or adolescents to operate this air compressor St...

Page 8: ...Reset 3 Air Intake Filter 4 Air Compressor Pump 5 Air tank drain valve 6 Tank Pressure Gauge 7 Outlet Pressure Gauge 8 Pressure Regulator 9 Oil Dipstick 10 Oil Drain 11 Discharge Line 12 115 Volt Elec...

Page 9: ...obstructions The filter can be removed for cleaning by using warm soapy water Rinse the filter and air dry Replace filter when necessary 4 AIR COMPRESSOR PUMP To compress air the pistons move up and...

Page 10: ...sary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire WARNING This pr...

Page 11: ...less pressure and clockwise for more pressure 6 If you notice any unusual noise or vibration stop the air compressor and refer to Troubleshooting SHUTDOWN 1 To stop the air compressor move the lever...

Page 12: ...e Plug cord into grounded outlet Move switch to AUTO position Turn air compressor off wait until motor is cool then press motor thermal overload red button firmly until click is heard Replace fuse or...

Page 13: ...city of the air compressor Either use a smaller tool or a larger air compressor REMEDY Remove clean or replace REMEDY Replace REMEDY Operate safety relief valve manually by pulling on ring If it still...

Page 14: ...st pressure regulator knob to proper setting or replace Clean or replace Check for leaks and repair Replace with larger hose or connectors Check the accessory air requirement If it is higher than the...

Page 15: ...uminium steel sleewer Valves Reed Single Head Aluminium Filter Canister Motor Pressure Switch Setting Cut out 125 PSI Cut in 95 PSI Controls Pressure switch Air tank Capacity 2 5 gallon Performance CF...

Page 16: ...improper storage or damages resulting during shipping 4 Deviation from operating instructions specifications and maintenance schedules 5 Labor charges loss or damage resulting from improper operation...