19
2) Follow
「
【
5
】
Drilling with Normal Mode
」
1) ͠ 9)in the page
14
•
15, and operate the drilling.
When you start to drill and the Core Bit hits to the reinforced steel,
the Feeding motor and the Drill Motor stop. And,
「
FC
」
and all lamp
on the digital display flash. (only FC lamp lights.)
3) Press the automatic stop setting button. The flashing of
「
FC
」
and all lamp on the digital display is released, and
the digital display changes to the current value display
and the clutch lamp lights, then, you can control the but-
ton again.
【7】
After the Operation
1) Turn off the switch of the Drill Head.
2) Unplug the plug of the SIDAF80.
3) Remove the wiring, then remove the SIDAF80 from the Drill Head.
4) Clean up for removing the Core Drill etc by following the instruction manuals of the Core Drill.
Possible to restart the button operation.
The picture shows the digital display
「
16
」
,
but setting current value is displayed.
POINT
Even if the automatic stop is released, it stops when the
Core Bit hits to the reinforced steel.