background image

KYOCERA SENCO Netherlands B.V.

Pascallaan 88

8218 NJ Lelystad, The Netherlands

+31 320 295 575

senco.com

EMEA: senco.eu

© 2020 by KYOCERA SENCO Netherlands B.V.

Operating Instructions

(Original Instructions)

NFE2DT2032020

Automatic Feeding System

SIDAF80

Summary of Contents for ISANTA SIDAF80

Page 1: ...ds B V Pascallaan 88 8218 NJ Lelystad The Netherlands 31 320 295 575 senco com EMEA senco eu 2020 by KYOCERA SENCO Netherlands B V Operating Instructions Original Instructions NFE2DT2032020 Automatic...

Page 2: ...ds WARNING CAUTION and POINT which mean as follows WARNING It is assumed that if the user uses the machine wrongly it would be the risks that the user could be died or injured CAUTION It is assumed th...

Page 3: ...ES 13 6 APPLICATIONS 13 7 OPTIONS Sold Separately 13 8 HOW TO USE 14 1 Preparation of the Core Drill 14 2 Mounting to the Core Drill 14 3 Wiring 15 4 Setting for Drilling Depth 16 5 Drilling with Norm...

Page 4: ...er to avoid to being caught in the rotating parts Wear rubber gloves and slip stopper footwear Wear cap or hair cover in case that you have long hair 5 Use Safety protection equipment Wear safety glas...

Page 5: ...e that the key and the wrench which are used for the inspec tion and adjusting are removed 14 The electric machines are maintained carefully Regarding exchanging the options please follow the instruct...

Page 6: ...ate Use the proper voltage which is indicated on the name plate of the Core Drill If you use the Core Drill over the indicated voltage the rotation of Drill Motor will be high speed which will cause t...

Page 7: ...rtain red lamp is off Press green ON RESET button again and make certain red lamp is on 3 Notes for Usage of the Reinforced Sensor Mode of Automatic Feeding System EHA WARNING 1 Do not use except the...

Page 8: ...he Core Bit cuts the reinforced steel and stops the rotation of the Core Bit and feeding at one time There fore there will be the scratch 2 3mm on the reinforced steel but depending on the machines or...

Page 9: ...e A C 230V 50Hz Max Power Consumption 52 8W Maximum Rotating Speed of Out put Shaft 2 0min 1 Applicable Core Drills SPF Core Drill E type SPN Core Drill E type SPZ Core Drill E type SPM Core Drill E t...

Page 10: ...ecrease the load for the Core Drill This figure shows the initial condition of connection of the power supply and of the lamp shows the lightning Drill Lamp It lights when the power supply for the Cor...

Page 11: ...onnect to the power supply CC is displayed in Normal Mode which will continue to light until you press either button Reinforced Sensor Mode When you connect to the power sup ply FC is displayed in Rei...

Page 12: ...automatic stop lamp flashes Light Press the automatic stop setting button Press the drill button Press the feeding button Displayed dE flashing Drill lamp flashes If the automatic stop is set it light...

Page 13: ...d manually by using the Drill Head of SENCO type Extension cable for Core Drill with CEE plug connection 5 STANDARD ACCESSORIES Instruction Manual SIDAF80 Attaching part Automatic drilling by installi...

Page 14: ...g the power supply cord with PRCD which is cut above 1 into CEE 17 Connector Mounting to the Core Drill 1 Follow the instruction manual of the Core Drill and set the Core Drill WARNING When mounting t...

Page 15: ...If the positioning pin is not fixed properly it will be extremely dangerous that SIDAF80 could come off Wiring 1 Turn off the switch of the Drill Head 2 Follow the below figure and wire The figure is...

Page 16: ...ctly Regarding how to release read Stopped by SENCO Stopper in the page 11 3 Be careful not to catch your fingers when mounting the SENCO stopper Drilling with Normal Mode 1 Make sure that CC lamp lig...

Page 17: ...rill Motor the condi tion of rotation of the Core Bit feeding speed and the condition of warping of the pole base If there is forced power press And if you hold down it is possible increasing and decr...

Page 18: ...trating through the slurry water will not stop 2 When the load of Drill Motor is high and the interference against drilled core generates after pene trating through the Drill Motor and feeding operati...

Page 19: ...al display changes to the current value display and the clutch lamp lights then you can control the but ton again After the Operation 1 Turn off the switch of the Drill Head 2 Unplug the plug of the S...

Page 20: ...Motor is burnout Repair for the Core Drill Feeding stops The transfer resistance of the Drill Head is too large due to the strong adjustment of the Drill Carriage of the Drill Head Release flashing by...

Page 21: ...nd turn the Core Bit back a little bit Then start to drill again The switch could turn off caused by the vibration Drilling speed is slow Cutting the thick reinforced steel Core Bit is blunt Contact o...

Page 22: ...e Core Drill The reinforced sensor mode of the SIDAF80 stops by detecting the load difference of unreinforced part and reinforced part of the reinforced concrete If the interference against drilled co...

Page 23: ...ed average emission sound pressure level at the work stations 70dB A Vibration levels for hand and arm 2 5m s2 13 WARRANTY We will guarantee the SENCO Automatic Feeding System SIDAF80 for 6 months fro...

Page 24: ...fter angivna i f ljande document EN61000 3 2 2019 EN61000 3 2 2019 EN61000 3 2 2019 EN55014 1 2006 A1 2009 A2 2011 EN55014 1 2006 A1 2009 A2 2011 EN55014 1 2006 A1 2009 A2 2011 Allekirjoitus Chris Kle...

Page 25: ...Blvd 4270 Ivy Pointe Blvd 4270 Ivy Pointe Blvd Cincinnati Ohio 45245 Cincinnati Ohio 45245 Cincinnati Ohio 45245 Version initiale 3 Avril 2020 Emisi n original 3 de Abril 2020 Edizione originale 3 Ap...

Reviews: