Testing a pulse-type bill validator
To test a pulse-type bill validator, you absolutely need the External Bill
Validator Module (EBVM). The EBVM is an option. You cannot test
any pulse-type acceptor without it. The EBVM is good in either 24
volts or 120 volts. Take note that if you own the previous model of
Vending Tester, the CT2, the EBVM you have will fit on the CT3.
The connector for the EBVM is located on the right side of the CT3 be-
hind the MDB connector. Connect the EBVM to the CT3.
The CT3/EBVM is capable of testing the following brands and models
of pulse type bill validator:
Type & Model
Plug into socket…
Ardac USA
P3
Ardac ABA
P2
Coinco BA30SA *
P2
Coinco BA32SA
P2
Conlux / Maka NB / NB2 / NBE (120-volt only) P4 & P5
Maka MKA / NBV
P2
Mars VFM series
P2
Mars VN2500
P2
Mars GL4 / GL5
P2
MEI AE Series gaming interface (24 volts)
P2