28
Pulse validator mode
START / STOP to begin
Press START/STOP to
test 24 volts or
Red button for 117
volts device
Pulse type Bill 24V
Pulse count = 000
Pulse type Bill 120V
Pulse count = 000
Once everything plugged in, press on
button #1
on the CT3. This but-
ton activates the external module. This button has no effect without
the EBVM.
Once button #1 is pushed, the display will prompt you to press START
to begin the sequence. After that, the CT3 will ask you what is the
voltage required to power-up your bill validator. If it is a 24-volt, press
the START button again. If it is a 120-volt acceptor, press on the red
button. As a protection, we have added a safety feature that requires
you to press the 117-volt button for at least 2 seconds before the CT3
actually sends that voltage. If you are not sure of the voltage of your
bill acceptor, please refer to identification label of the bill validator
BEFORE applying power. Applying the wrong voltage may result in
damages to the bill acceptor, the EBVM or the CT3 itself.
When ready to test, the display will prompt:
If you insert a bill and if this bill is accepted, the pulse count will in-
crease by the value of the bill. Along with the pulse count, a beep will
sound so that you do not have to look at the display to know if the bill
validator gives the pulses.
After the CT3 has received the last pulse of the bill, the total of pulses
will stay on the display for about 2 seconds before switching back to
zero. Because of the nature of a pulse-type bill validator, the only
message you will see on the display is the pulse count.
Do not forget to disable the ACCEPT LINE to make sure the bill accep-
tor does not accept bills. Note that some bill acceptors may not take
into account the accept line and accept bills all the time.