EN
45
commeo initial operation/Setting by radio
Note for settings under point 5.2.: The motor must be selected for this setting with a trans-
mitter in SELECT mode (Status LED flashes slowly in orange). After completing the setting,
the motor is still selected (see 5.).
5.2.1. Semi automatic setup-mode, deletion and semi-automatic setting of the upper end
positions
in operation bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in semi automatic
setup-mode. The drive will only find the upper end limit automatically.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit stop
without interruption, until the motor is automatically switched off.
Operation
Drive
9 s
Press the STOP button of the transmitter for 9 seconds.
Note: Not required for the initial installation or after
resetting to factory defaults.
or
STOP
STOP
Move the motor with the UP or DOWN button down-
wards to the requested lower end limit.
STOP
STOP
Run against the limit stop at the top without stopping;
the motor stops automatically.
The correct direction of rotation assignment has been
made. Perform a test run: The drive moves up against
the limit stop and relieves shortly.
Note: The transmitter may not yet have been pro-
grammed. See point 5.2.4. to program a transmitter.