EN
37
Setting of the end positions
4. Setting of the end positions
4.1. Delivery status
In the SELVE delivery status no end positions or transmitters are programmed into the radio
motor!
In this state, the motor can be operated in deadman’s operation only. Safety functions are
deactivated at delivery and will only become active after both end positions are set.
In delivery status the SE Plus-com is in semi automatic programming mode. This will be signal-
ized by a short up and down movement when connected to mains.
4.2. Setup functions
The end positions setting of a SELVE radio motor is possible via:
• the setting switch for radio motors (item no. 290109 or 291009) or with
• any standard switch (only in semi-automatic mode)
or with
• any standard commeo transmitter.
4.3. Mechanic requirements
The operation of the SE Plus-com as roller shutter motor is possible by using safety springs or
blocking springs. When using the SE Plus-com as awning motor the awning fabric will often
be connected directly with the fabric shaft.
Caution: There is no automatic setting of the lower end limit when using the SE Plus-com.
The lower end limit has always to be run-up to or also set.
Caution: When setting in semi automatic and manual setting mode, a fixed upper end limit
has to exist if this end limit has to be recognized from the motor automatically.
4.4. Selection table for settings
Setup-mode/end positions in operation
Setting switch
commeo radio
Semi automatic setup- mode
bottom position, top stop/release*
4.5.1. (page 39)
5.2.1. (page 45)
Manual setup- mode
bottom position, top stop/release*
4.5.2. (page 40)
5.2.2. (page 46)
Manual setup -mode
bottom position, bottom stop
4.5.3. (page 41)
5.2.3. (page 47)
* Both setting procedures are leading to the same result: bottom position: point, top posi-
tion: limit stop/relief.