7 TECHNICAL SPECIFICATIONS
NEOMIG
3500
NEOMIG
4500
Power supply voltage U1 (50/60Hz)
3x230/400Vac ±15%
3x230/400Vac ±15%
Zmax (@PCC)
*
262m
Ω
176m
Ω
Slow blow line fuse
35/20A
50/30A
Maximum input power (KVA)
16.6 KVA
24 KVA
Maximum input power (KW)
15kW
22.9kW
Power
factor
PF
0.96
0.96
Max.
input
current
I1max
23.9A
34.8A
Effective
current
I1eff
15.1A
22A
Duty factor (x=25°C)
(x=40%)
350A
(x=45%)
450A
(x=60%) 320A
390A
(x=100%) 260A
320A
Duty factor (x=40°C)
(x=35%)
350A
(x=40%)
450A
(x=60%) 300A
370A
(x=100%) 240A
300A
Adjustment
range
I2
30-380A
30-480A
Step
3x10
3x10
Open
circuit
voltage
Uo
50V
50V
IP
Protection
rating IP21S
IP21S
Insulation
class
H
H
Dimensions (lxdxh)
1060x400x780 mm
1060x400x780 mm
Weight
123
Kg.
139
Kg.
Power supply cable
4x6 mm2
4x6 mm2
Manufacturing
Standards
EN
60974-1
EN
60974-1
EN
60974-5
EN
60974-5
EN
60974-10
EN
60974-10
Wire feeder rated powe
90W
90W
No
rolls
2
(4)
2
(4)
Standard
roller
1.0-1.2
(STD)
1.0-1.2
(STD)
Tractable rollers
0.6-0.8-1.0-1.2-1.6 solid wire
0.6-0.8-1.0-1.2-1.6 solid wire
0.8-1.0-1.2-1.6
aluminium
wire
0.8-1.0-1.2-1.6
aluminium
wire
1.2-1.4-1.6-2.0-2.4
flux-core
wire
1.2-1.4-1.6-2.0-2.4
flux-core
wire
Wire
feed
speed
1.5÷22
m/min.
1.5÷22
m/min.
Wire
feed
button
yes
yes
Gas
test
button
yes
yes
Synergic
programs yes
yes
Steel
rolls yes
yes
Connector for Push-Pull torch
no
no
NEOMIG 3500
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment complies with EN/IEC 61000-3-12 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.
NEOMIG 4500
*
This equipment complies with EN/IEC 61000-3-11/12 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.
Summary of Contents for Neomig 3500
Page 182: ...182 1 3 1 4 11 35 1 5...
Page 184: ...1 8 IP S IP21S 12 5 mm 2 2 1 A B 90 B 2 2 10 2 3 400V 230V 184...
Page 185: ...185 15 Vnom 400V 320V 440V 400V 15 2 1 5 2 4 MIG MAG MIG 1 5 6 2 2 3 4 10 15...
Page 189: ...189 4 5...
Page 190: ...190 Reset encoder...
Page 191: ...191...
Page 192: ...192 6 6 1 MIG 6 1 1 SHORT ARC 1a SHORT a SPRAY ARC b SPRAY ARC 1b 6 1 2 2 3 2 3 1a 1b...
Page 198: ...198 NEOMIG 4500...
Page 202: ...202 51 06 028 NEOMIG 4500...
Page 206: ...206...