Further explanations of the above:
GREEN LED:
This LED lights if +5Vdc is present on card
15.14.254 .
Therefore,
if
the machine is connected to the mains
and
if
the master switch is closed
and
if
the power circuits of the command and control
circuits are operating
then
the green LED is on
Vice versa
if
the green LED is off
then either
the machine is not connected
correctly to the power mains
or
the master switch is open
or
the power circuits of the command and
control circuits are not operating
116
Description of diagnostic indications
6) DESCRIPTION OF DIAGNOSTIC INDICATIONS.
6.1)
Diagnostic indications external
G 240 (FP104) (
see fig. n°31
) :
The G 240 has two leds on the front panel with diagnostic
functions:
FIG. 31
Position
L1
L2
Colour
GREEN
YELLOW
Status under
normal
conditions
ON
OFF
Meaning
Machine powe-
red and master
switch closed
Protection devi-
ce NOT active
YELLOW led:
this led is off when the machine is operating
normally. If it comes on, it may indicate overtemperature of
the output rectifier circuit, the inverter or the levelling induc-
tance with consequent halting of current delivery by the
machine. Alternatively it can indicate cut-in of the overvolta-
ge or undervoltage protection (with consequent halting of
current delivery).
Therefore
if
the LED is on
then
either
the machine has exceeded work
cycle limits
or
the fan is not operating
or
air flow is obstructed from the outside
or
the line voltage has exceeded the
permitted limits
Summary of Contents for Genesis 240 TLH
Page 1: ...REPAIRS MANUAL E N G L I S H Genesis 240 Genesis 240 TLH...
Page 9: ...Description of machine operation 91 n m k a o q r l c b i p j d s e f g h e FIG 6...
Page 11: ...Description of machine operation 93 n m k a o q r l c b i p j d s e f g h e FIG 8...
Page 22: ...LAY OUTS OF CARDS...
Page 23: ...Lay outs of cards 105 Card 15 14 233 Fig 20...
Page 24: ...106 Lay outs of cards Card 15 14 236 side A Fig 21...
Page 25: ...Lay outs of cards 107 Card 15 14 236 side B Fig 22...
Page 26: ...108 Lay outs of cards Card 15 14 236 side C Fig 23...
Page 27: ...Lay outs of cards 109 Card 15 14 254 side A Fig 24...
Page 28: ...110 Lay outs of cards Card 15 14 254 side B Fig 25...
Page 29: ...Lay outs of cards 111 Card 15 14 254 side C Fig 26...
Page 30: ...112 Lay outs of cards Card 15 14 254 side D Fig 27...
Page 31: ...Lay outs of cards 113 Card 15 14 192 Fig 28...
Page 32: ...114 Lay outs of cards Card 15 14 239 Fig 29...
Page 33: ...Lay outs of cards 115 Card 15 14 240 Fig 30...
Page 58: ...140 Diagnosis procedure J9 connector frontal side FIG 36 Card 15 14 192 FIG 37...
Page 59: ...Diagnosis procedure 141 FIG 38 Card 15 14 233 FIG 39...
Page 60: ...142 Diagnosis procedure Card 15 14 254 version 1 soldering side FIG 40A...
Page 61: ...Diagnosis procedure 143 Card 15 14 254 version 2 soldering side FIG 40B soldering side view...
Page 62: ...144 Diagnosis procedure Card 15 14 236 FP106 FIG 41...
Page 63: ...Diagnosis procedure 145 FIG 43 H F 15 14 192 wring diagrama FIG 42...
Page 64: ...146 Oscillograms Oscillogram 1 Oscillogram 2...
Page 65: ...Oscillograms 147 Oscillogram 3 Oscillogram 4...
Page 66: ...148 Oscillograms Oscillogram 5 Oscillogram 6...
Page 67: ...Oscillograms 149 Oscillogram 7 Oscillogram 8...
Page 68: ...150 Oscillograms Oscillogram 9 Oscillogram 10...
Page 69: ...Oscillograms 151 Oscillogram 11...
Page 73: ...Parts dismantling and re installation procedure 155 FIG 44...
Page 74: ...156 Parts dismantling and re installation procedure FIG 45...
Page 75: ...Parts dismantling and re installation procedure 157 FIG 46 FIG 47...
Page 76: ...158 Parts dismantling and re installation procedure FIG 48...
Page 79: ...Operating tests and settings 161 Card 15 14 239 FIG 49...
Page 80: ...162 Operating tests and settings Card 15 14 254 FIG 50...
Page 81: ...Operating tests and settings 163 FP106 FIG 51...