6
Functions
6-1. Memory Function
This meter can store up to nine measured values in memory for incident light
and reflected light simultaneously. This function can be used in all modes except
Illuminance/Luminance measuring and Multiple (cumulative) Flash modes.
6-1-1. Memory
1.
Press the Measuring button
8
on the side of
meter to take a measurement and display a
value on the measuring screen.
2. Press the Memory button
5
to memorize
measured value. And M 1 will appear at the
top of the screen to indicate one value has
been memorized and an indicator will appear
on the analog scale.
3. Repeat steps 1 and 2 as desired to memorize
up to 9 values for comparison.
•
Memory Function cannot be used with the following modes.
• Illuminance Measuring Mode (lux, fc)
• Luminance Measuring Mode (cd/m
2
, fl)
• Cord Flash Accumulative Mode
• Cordless Flash Accumulative Mode
• Radio Flash Accumulative Mode (for L-478DR Series only)
•
The tenth or more measurement will be displayed but can not be memorized.