Setting the Language
Programming Operation
-
-
-
-
-
Pump Functions
Max flow rate
Alarm Relay
Language
P100%
N.Open
English
PROG
+
-
Makes it possible to select the language. The pump is set in
English in the factory.
Changes can be made by pressing the
key, then using
the
keys to set the new value. Press
to
confirm and return to the main menu
Paragraph 1 – Manual Dosage
Programming Operation
+
-
Pump Funtions
Configuration
Pump Functions
PROG
Manuel
The pump operates in constant mode. The flow can be manually regulated
by pressing the
keys at the same time to increase the flow, or
the
keys to decrease it.
Display during Operation
Display during Setting (MODE key)
MAN
F
F
F
Lev Stop P100%
Operating mode
•
Man = Manuel
Alarms and statuses
•
Liv = Level alarm
•
Fls = Debit alarm
FLOW sensor
status
Pump status
•
Empty = pump in start
•
Stop = pump stationary
•
Paus = pump in pause
Current dosage value
(depends on the selected unit
of measurement)
•
Percentage, Frequency,
l/h, Gph, ml/m
F320s/m
P100%
Operating mode
•
Displays the corresponding frequency value
Current dosage value
•
The maximum flow can be modified by
pressing the + or – keys at the same time
EM00136063 rev.
1.0
3