Programmiermenü Tekna TPR 

 

You can access the programming menu by pressing the 

 key for over three seconds. The 

 

 keys can 

be used to run through the menu items, with the 

 key being used to access changes. 

The pump is programmed in constant mode in the factory. The pump automatically returns to the operating mode 

after 1 minute of no activity. Any data entered in these circumstances will not be saved. The 

 key can be used 

to exit the various programming levels. Upon exiting programming, the display will show: 

Exit Exit 

No Save 

 

 

Save 

   

 to confirm the selection

 

 

 

+

-

PROG

Temperature Man.

25 °C

Probe Calib.

On

Configuration

Pump Functions

Max flow rate

100%

Alarm Relay

N.Open

Language

English

O.F.Alarm

 0m

Resolution

0.01

Alarm Band

2.00 pH

Prop. Band

0.50 pH

Setpoint Type

Acid

Setpoint

 7.00 pH

Prog

 Configuration

+

+

-

-

Pump 

Functions

pH Measure

Pump 

Functions

Redox Measure

Pump 

Functions

Manual

Paragraph 1

Paragraph 5

Paragraph 4

Paragraph 6

Paragraph 7

Paragraph 8

Paragraph 9

Paragraph 10

Paragraph 3

Paragraph 2

Main

Menu

Functions

Menu

Setting

Menu

Paragraph 11

 

EM00136063 rev. 

1.0 

2

Summary of Contents for TEKNA TPR 600

Page 1: ...nal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Access to the pump calibration menu If in Off mode the calibration menu is not activated Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through...

Page 2: ...ous programming levels Upon exiting programming the display will show Exit Exit No Save Save to confirm the selection PROG Temperature Man 25 C Probe Calib On Configuration Pump Functions Max flow rate 100 Alarm Relay N Open Language English O F Alarm 0m Resolution 0 01 Alarm Band 2 00 pH Prop Band 0 50 pH Setpoint Type Acid Setpoint 7 00 pH Prog Configuration Pump Functions pH Measure Pump Functi...

Page 3: ...mode The flow can be manually regulated by pressing the keys at the same time to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key MAN F F F Lev Stop P100 Operating mode Man Manuel Alarms and statuses Liv Level alarm Fls Debit alarm FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosage value dep...

Page 4: ...l is triggered if the pH value does not reach the set point The measurement resolution 1 or 2 decimal points Deactivation activation of the calibration procedure Manual temperature value in ºC default or ºF The maximum frequency can be modified during operation by pressing the keys at the same time to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE...

Page 5: ... at the same time to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key High F F F 560mV Lev Stop P100 Setpoint type High Low Alarms and statuses Cal calibration not completed Lev Level alarm Flw Flow alarm Alm Measurement outside alarm band OFA O F A alarm Flow sensor status Potential Redox measurement value Pump status Empty pump in start Stop p...

Page 6: ...ike using the keys and confirm by pressing the key AUTOMATIC the pump makes 100 strikes which are started by pressing the key At the end of this process enter the quantity sucked up by the pump using the keys and confirm by pressing the key The entered figure will be used in flow calculations Paragraph 7 Statistics Programming Operation Statistic Statistic Statistic Statistic Reset Hours 10 Hours ...

Page 7: ...key and you can then use the keys to set the value Confirm by pressing the key Press to return to the main menu Paragraph 10 Level Alarm Programming Operation Alarm Level Alarm Flow Alarms Level Stop Alarms Level Alarm Stop Alarm PROG ESC This makes it possible to set the pump when the level sensor alarm is activated In other words you can decide whether to stop dosage Stop or simply activate the ...

Page 8: ...ss the key A 60 second countdown necessary to complete calibration will appear on the display If the alignment quality is below 50 an error message appears on the display and you should press to exit calibration the pump exits automatically after 4 seconds If the quality is above 50 the value is shown on the display and after pressing the key the buffer solution at pH 4 or 9 will be requested At t...

Page 9: ...ppears on the display Insert the probe in the bottle and press the key A 60 second countdown necessary to complete calibration will appear on the display If the alignment quality is below 50 an error message appears on the display and you should press to exit calibration the pump exits automatically after 4 seconds If the quality is above 50 the value is shown on the display and you should press t...

Page 10: ...xternal impulses it returns the memorised strokes Fixed alarm LED Flashing word Flw I e Man F Flw P100 Active flow alarm The pump has not received the programmed number of signals from the flow sensor Press the key I e Parameter Error PROG to default Communication error with the eeprom Press the key to restore the default parameters Flashing word OFA Flashing word stop I e High 475 mV OFA Stop P 7...

Reviews: