37
8. TROUBLE-SHOOTING
Use adequate tools and protection.
Problem
Cause
Remedy
Auger stop
Clogging of material
- Proceed to the counter-rotation of the
augers.
Breakage of the transmission chain
- Repair the chain using a joining link
- Check the possible reasons of the
failure, which can be: - not sharpened
knives - rotated knives - material
extremely resistant to cutting
The propeller shaft doesn't turn
- Cut the propeller shaft key
Unloading belt
The solenoid valve doesn't work
- Check the electric control connections,
if necessary repair.
Broken tubing
- Replace
Clogged filter
- Replace the filter
Hydraulic pump not working
- Replace the pump
Hydraulic motor out of service
- Replace the hydraulic motor
Cut hydraulic motor key
- Replace the key
Lack of oil
- Restore the level
No augers reverse
Damaged or unset pressure switch
- Change or reset the pressure switch or
call SEKO assistance
Hydraulic pump or motor out of
service
- Call SEKO assistance
Frequently augers reverse
Clogging of material
- Check the possible reasons of the
failure, which can be: - not sharpened
knives - rotated knives - material
extremely resistant to cutting
Damaged or unset pressure switch
- Change or reset the pressure switch or
call SEKO assistance
Damaged or unset timer
- Change or reset the timer or call SEKO
assistance
Augers dephased
- Make the timing (see par 5.2 Timing of
augers” of this manual).
Discharge door doesn't open
Press-button doesn't switch over
- Replace or call SEKO assistance
The solenoid valve doesn't work
- Check the electric control connections,
if necessary repair.
The discharge door is embedded
- Reset the bearings bush.
Noises from the tank
Chains loosening
- Adjust
Broken bearings
- Replace
Reduction gears without oil
- Fill up
Chains without oil
- Lubricate the transmission chains
Counter blades or augers blades are
broken or loosen
- Replace or fix
Noises from the hydraulic motor or
pump
Motor or pump are broken
- Replace or call SEKO assistance
The electric motor doesn't work
Termic block
- Leave the motor to cool and see
instructions for controls use in this
manual to restart it.
Fuse blowed
- Replace
Damaged electric motor
- Call SEKO assistance
Summary of Contents for SAM 5-ME
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 8: ...NOTE ...
Page 14: ...7 2 5 Overall dimensions ...
Page 19: ...12 4 2 Control s panel instruction use Fig 13 ...
Page 31: ...24 6 MAINTENANCE Fig 49 ...
Page 41: ...34 6 4 Sticker plan Fig 63 ...
Page 43: ...36 7 HYDRAULIC DIAGRAM Generic ...
Page 45: ......
Page 46: ...Via Gorizia 90 35010 CURTAROLO PD ITALY TEL 0039 049 9699888 FAX 0039 049 9620403 ...