14
1) Display control ADX ( 1 Fig. 13 )
This control panel allows utilisation of some very
important machine’s peculiarities.
Before starting to work with your new machine please
read what is written in the following pages of the manual
maintenance and use instructions for a correct machine
running.
2) Main line light ( 2 Fig. 13 )
It shows that tension is present in the general switch ( 16
Fig. 13 ). In case of light off, before starting any action
aimed to repair the damaged light, please check that the
general main switch is in 0 or OFF position ( Fig. 14 ).
3) Emergency light ( 3 Fig. 13 )
This light is ON only if the emergency switch is in ON
position ( 31 Fig. 13 ), light will remain ON if the
emergency switch is ON. Light will be off only if
emergency switch will be put in OFF position.
4) Electric wiring protection light ( 4 Fig. 13 )
This light will be on if protections of the electric circuit
are activated. Please check the pertaining use and
maintenance instructions of this machine.
5) Starter light ( 5 Fig. 13 )
This light is on if in the electric board an input is given.
( it shows a tension input).
6) Forward direction start up light ( 6 Fig. 13 )
This light is on by activating the push button forward
drive ( 9 Fig. 13 ), and shows the forward direction
movement of the augers.
7) Right side discharging door closed push
button ( 7 Fig. 13 )
By pressing this push button the discharge door starts
closing (Fig. 15). Light will be on as soon as the button is
pressed showing the operation. This button has no clutch
and terefore it tends to go back when it is released and the
discharging door mantains tha position.
8) Stop push button of direction movement ( 8
Fig. 13 )
By pressing this button all the other buttons ( 9 – 24 Fig.
13 ) are disactivated. In case of necessity of the augers
inverted rotation, before pressing the pertaining button,
you must first press the stop button and wait until the
augers are in still position.
Fig. 14
Fig. 15
Fig. 16
Summary of Contents for SAM 5-ME
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 8: ...NOTE ...
Page 14: ...7 2 5 Overall dimensions ...
Page 19: ...12 4 2 Control s panel instruction use Fig 13 ...
Page 31: ...24 6 MAINTENANCE Fig 49 ...
Page 41: ...34 6 4 Sticker plan Fig 63 ...
Page 43: ...36 7 HYDRAULIC DIAGRAM Generic ...
Page 45: ......
Page 46: ...Via Gorizia 90 35010 CURTAROLO PD ITALY TEL 0039 049 9699888 FAX 0039 049 9620403 ...