3-15
(3) Preventing
Overheat
To prevent the motor from overheating, the drive time and drive ratio are limited.
Follow the Table 3-7 shown below to set an operating time and a pause time of the motor.
Table 3-7 Maximum Drive Time and Drive Ratio
Motor drive voltage V
P
(V)
9.5V
≥
V
P
>8.5V
8.5V
≥
V
P
>7.5V
7.5V
≥
V
P
>6.5V
6.5V
≥
V
P
>5.5V
5.5V
≥
V
P
≥
4.75V
Drive pulse rate
(pps)
Maximum
continuous
drive time
(s)
Drive ratio
Drive ratio
Drive ratio
Drive ratio
Drive ratio
320
to 560
450
85%
85%
85%
85%
90%
560
to 800
450
85%
85%
85%
90%
90%
800
to 1040
450
85%
85%
85%
90%
95%
1040 to 1280
450
85%
85%
90%
95%
100%
1280 to 1520
450
85%
90%
90%
100%
100%
1520 to 1760
450
85%
90%
95%
100%
100%
1760 to 2000
455
85%
90%
100%
100%
×
2000 to 2240
465
85%
95%
100%
100%
×
2240 to 2480
485
90%
100%
100%
×
×
2480 to 2720
515
90%
100%
100%
×
×
2720 to 2960
575
95%
100%
×
×
×
2960 to 3200
665
95%
100%
×
×
×
3200
1445
95%
100%
×
×
×
×
: Not Allowed to use
( )
(%)
100
×
Time
Pause
+
Time
Drive
Time
Drive
=
%
Ratio
Drive