background image

23 

To release split time   
(Ex.: 28 minutes and 32 
seconds 56) 

 

 

 

Total time 
measurement in 
progress is displayed.
 

 
 
 
“SP” is shown on display monitor only 

To stop Stopwatch 
(Ex.: 2 hours, 20 minutes 
and 23 seconds72) 

 

 

 

Stopwatch is stopped.

“SP” is shown on 
display monitor only. 
 

To reset Stopwatch 

 

 

Stopwatch is reset to 
“0”. 

“SP” is shown on 
display monitor only. 

 Operation Procedure: To Measure Times of First and Second Runners 

 Operation 

Timer 

section 

2nd timer 

section 

Section for 
points, etc. 

Action/Remarks

Display monitor 

Select split time display. 

 

 

 

 

“SP” is shown on 
display monitor only. 

To start Stopwatch 

 

 

 

Measurement is 
started. 

“SP” is shown on 
display monitor only. 

To measure time of 1st 
runner 
(Ex.: 26 minutes and 13 
seconds 08) 

 

 

 

Time of 1st runner 
(not in progress) is 
displayed, and 
flashing “SP” is 
shown. 
*Measurement is 
continued internally. 

“SP” flashes on both 
display monitor and 
display panel. 

To measure time of 2nd 
runner 

 

 

 

Time of 1st runner 
(not in progress) is 
displayed, and “SP” 
(not flashing) is 
shown. 
*Measurement is 
continued internally. 

“SP” is shown on both 
display monitor and 
display panel. 

To display time of 2nd 
runner 
(Ex.: 28 minutes and 32 
seconds 56) 

 

 

 

Time of 2nd runner is 
displayed instead of 
that of 1st. 

“SP” is shown on both 
display monitor and 
display panel. 

To reset Stopwatch 

 

 

 

Stopwatch is reset to 
“0”. 

“SP” is shown on 
display monitor only. 

 Operation Procedure: To Measure Lap Time 

 Operation 

Timer 

section 

2nd timer 

section 

Section for 
points, etc. 

Action/Remarks

Display monitor 

Select lap time display. 

 

 

 

 

“LP” is shown on 
display monitor only. 

 

To start Stopwatch 

 

 

 

Measurement is 
started. 

“LP” is shown on 
display monitor only. 

 

To measure 1st lap time 
(Ex.: 26 minutes and 13 
seconds 08) 

 

 

 

1st lap time (not in 
progress) is 
displayed, and 
flashing “LP” is 
shown. 
*Measurement is 
continued internally. 

“LP” flashes on both 
display monitor and 
display panel. 

To release lap time 
(Ex.: 28 minutes and 32 
seconds 56) 

 

 

 

Total time 
measurement in 
progress is displayed.

 
 
 
“LP” is shown on display monitor only. 

To measure 2nd lap time 
(Ex.: 23 minutes and 9 
seconds 27) 

 

 

 

2nd lap time (not in 
progress) is 
displayed, and 
flashing “LP” is 
shown. 
*Measurement is 
continued internally. 

“LP” flashes on both 
display monitor and 
display panel. 

(6) 

Display can be changed 
over to split time as 
required. 

 

 

 

Split time is 
displayed. 
Flashing “SP” is 
shown. 

“SP” flashes on both 
display monitor and 
display panel. 

Summary of Contents for KT-601

Page 1: ...Thank you for purchasing SEIKO SPORTS COUNTER KT 601 Before using your SEIKO SPORTS COUNTER please read this manual carefully for its proper use and care Keep this manual handy for ready reference...

Page 2: ...ns or alterations performed by other than SEIKO or a servicing contractor authorized by SEIKO SAFETY ALERT SYMBOLS The symbols and terms used in this manual have the meaning as explained below WARNING...

Page 3: ...6 4 8 Boxing 17 4 9 Programmable Timer 19 4 10 Pace Setter 21 4 11 Stopwatch 22 4 12 Timer with Warning Buzzer 25 4 13 Clock Alarm 26 4 14 Factory Default Settings Initial Setting of Each Event Functi...

Page 4: ...ainst unauthorized disassembly repair or modification Unless you are a qualified electrician never try to disassemble repair or modify the Product For repair serve contact your nearby SEIKO dealer or...

Page 5: ...cession an interval of at least 5 seconds should be provided between the switch operations Before moving the Product be sure to turn off the power switch An electric shock or malfunction may result Wh...

Page 6: ...Buzzer Guest Home Power switch POWER Connector for external buzzer EXT BUZZER Connector for grip switch GRIP SWITCH Operation Panel Connector for adaptor with power cable DC IN Connectors for data si...

Page 7: ...the manner of ringing of the buzzer can be selected from 5 patterns namely high and continuous high and intermittent silent low and continuous and low and intermittent as shown below No mark While in...

Page 8: ...e default settings the following procedure of confirmation of settings and adjustment need not be performed Method of Confirmation Adjustment of Settings Operation Timer section 2nd timer section Sect...

Page 9: ...o adjust 24 seconds Operation can be made only while timer is stopped Counting restarts Pressing Clear button resets time to 24 and stops timer 5 To adjust game time Operation can be made only while g...

Page 10: ...ay 3 To change court If possession or H G display is shown court change is made automatically 4 To clear points Only points are cleared Time possession and 24 sec timer remain unchanged Operation Proc...

Page 11: ...mer setting mode 2 To adjust timeout time from 60 seconds to any desired amount of time Operation can be made at any time while setting mode is activated 3 To change color of timeout time display Colo...

Page 12: ...Foul Settings Operation Timer section 2nd timer section Section for points etc Action Remarks Display monitor 1 To activate team foul setting mode LED on front side is green LED on front side is red 2...

Page 13: ...er section Section for points etc Action Remarks Display monitor 1 To activate timeout interval time setting mode 2 To register interval time and move to mode to set time to sound end of interval buzz...

Page 14: ...h press of or indication changes in the order of 1 2 blank or 2 1 blank respectively 2 To display set count period Set count period marks light up one by one from left to right up to 5 sets 3 To chang...

Page 15: ...tton while in the setting mode the contest timer can be set to count upward UP and downward DOWN alternately Operation Procedure Start of Contest Ex Contest Time 5 minutes Osaekomi Time 25 seconds Ope...

Page 16: ...onds of osaekomi time has elapsed ippon and contest is ended Contest and osaekomi timers stop automatically with a buzzer sound Buzzer 3 2 When osaekomi is escaped before osaekomi time has elapsed and...

Page 17: ...order of 0 15 30 40 After 40 button will not change points Press button to reset points of both sides to 0 3 In case of deuce button for player having gained advantage will not change points Press but...

Page 18: ...won and games won of both sides are all reset to 0 Operation Procedure 1st 2nd Serve Display Operation Timer section 2nd timer section Section for points etc Action Remarks Display monitor 1 To indic...

Page 19: ...final can be adjusted 3 To register setting and move to final game setting 4 Points at which Advantage mark is shown in final game can be adjusted 5 To register setting and change over to game mode O...

Page 20: ...e to sound end of round warning buzzer 30 seconds before end interval 1 minute and time to end of interval warning buzzer 5 seconds before end Operation Timer section 2nd timer section Section for poi...

Page 21: ...d Warning buzzer rings 30 seconds before end of round warning buzzer 4 End of Round 1 Start of interval timer Buzzer sounds at the same time as Round 1 ends and interval timer starts counting automati...

Page 22: ...minutes and 30 seconds Program 2 3minutes and 20 seconds number of times repeated 15 times Operation Timer section 2nd timer section Section for points etc Action Remarks Display monitor 1 To activate...

Page 23: ...same time as Program 2 ends Program 1 starts counting for 2nd time with a buzzer sound Buzzer 5 When all Programs are completed as designated display returns to Program 1 before start Timer is automa...

Page 24: ...ythm Tempo 3 To register settings and change over to pace setter function 1 With each press of button while in the setting mode the display of number of times the tempo sound indication is repeated ca...

Page 25: ...ks Display monitor 1 Select Stopwatch Either lap or split time display can be used LP is shown on display monitor only 2 To start Stopwatch Measurement is started LP is shown on display monitor only 3...

Page 26: ...lay panel 5 To display time of 2nd runner Ex 28 minutes and 32 seconds 56 Time of 2nd runner is displayed instead of that of 1st SP is shown on both display monitor and display panel 6 To reset Stopwa...

Page 27: ...ed Operation Timer section 2nd timer section Section for points etc Action Remarks Display monitor 1 To measure 3rd lap time and stop Stopwatch 3rd lap time is displayed and Stopwatch is stopped LP is...

Page 28: ...is set for the time of a Program during the setting mode setting procedure of the rest of the Programs will be cancelled To register settings and change over to Timer display 1 With each press of but...

Page 29: ...ting 1 To set Program 2 and more programs follow the above steps To register settings and change over to Clock display 1 Once the Clock has been set and started it continues operating even while the a...

Page 30: ...1 Basketball 24 Sec Timer LED color of 24 Red Program 1 P1 10 min Points at which advantage mark is displayed before final game 4 Program2 P2 2 min Program 3 P3 10 min Program 4 P4 10 min 7 Soft Tenn...

Page 31: ...uttons of Wireless Remote Controller No Event Function A B C D E F G H I J 1 Basketball 24 Sec Timer 10 24 25 9 23 22 20 19 17 16 2 Basketball Timeout Timer 10 9 23 22 20 19 17 16 3 Basketball Team Fo...

Page 32: ...h new ones before the remote controller is used for a sports event When inserting new batteries check that and terminals of R03 AAA dry batteries are properly aligned in the compartment 4 Standard sig...

Page 33: ...hey are connected in a serial manner turn on other devices one by one in order from the one nearest to the master device Otherwise the devices may show abnormal displays or operate improperly Also do...

Page 34: ...nge places 6 3 Receiver Sports Printer To use CT 1000 as a master device and connect KT 601 as a receiver Setting of KT 601 used as a receiver Press Equipment Connection button to select 3 Receiver Sp...

Page 35: ...mer section 130 mm Point section 120 mm Second timer section 110 mm Display High intensity LED Operational temperature range 0 C 40 C except under direct sunlight Weight Approx 4 3 kg main unit 0 7 kg...

Page 36: ...owing cases 1 Failure or damage caused by misuse or carelessness 2 Failure or damage caused by improper repair or modification 3 Failure or damage caused by improper handling such as dropping of the P...

Reviews: