STEP 4
ENTER THE CODE FOR ENCODE
DIVIDE
THE TONE
BY
1.436
AND ENTER THE RESULT.
MUST
ENTER 4 DIGITS
.
288.5 / 1.436 = 200.91 ROUND TO 0201 AND ENTER
1130.0 / 1.436.= 786.91 ROUND TO 0787 AND ENTER
HOLD THE “
#”
IN FOR 5 SECONDS TO EXIT OR PROCEED TO NEXT OPTION
CLR MEMORY?
YOU ARE GIVEN THE CHOICES OF:
CLEARING THE ENCODER MEMORY
CLEARING THE DECODER MEMORY
CLEARING THE CUSTOM TONES MEMORY
SELECT “YES” OR “NO” FOR ANY OR ALL OF THE OPTIONS
HOLD THE “
#”
IN FOR 5 SECONDS TO EXIT OR PROCEED TO NEXT OPTION
INTERFACE ADD/DEL
AN INTERFACE UNIT CAN BE USED WITH THE SEIADVISOR TO CONNECT IT TO THE OVERHEAD
SPEAKER SYSTEM, LIGHTING ETC.
THIS OPTION MUST BE ACTIVATED TO WORK WITH THE INTERFACE.
WHEN A CALL IS RECEIVED THE INTERFACE UNIT PROVIDES THE FOLLOWING FUNCTIONS:
-ALERT TONES (VOLUME ASCENDING) ARE SENT OVER THE SPEAKER SYSTEM.
-RADIO TRAFIC IS SWITCHED TO THE SPEAKER SYSTEM.
-A RED LIGHT CAN BE ACTIVATED IN BUNK ROOM AND 30 SECS LATER THE ROOM LIGHTS COME ON
FOR 10 MINS.
-PROGRAMMABLE RELAY IS PROVIDED FOR THE STOVE, LIGHTS, DOORS ETC.
-THE CONTROL IS DONE THROUGH THE BUILDING WIRING
WITH Z WAVE OR UPB INTERFACES AND SWITCHES.
HOLD THE “
#”
IN FOR 5 SECONDS TO EXIT OR PROCEED TO NEXT OPTION
12