22
3.8.2.
LEG-LEVELLING PROCEDURE
·
This operation requires 2 people. Ensure that all leg adjusters are in contact with
the floor otherwise the machine may move and cause injury.
·
Only QUALIFIED SERVICE PERSONNEL should carry out this operation.
This machine has 4 castors and 8 leg adjusters. When the installation position is decided, unscrew the leg
adjusters so that they raise each castor a minimum of 5mm from the floor. Make sure the machine is level.
1. Move the machine to its final position.
2. Adjust the leg adjusters as shown until the
castors are approximately 5mm off the floor and
the machine is level.
Ensure adequate ventilation is maintained as detailed below
Summary of Contents for Virtua Cop 3 Deluxe Type
Page 12: ...9...
Page 48: ...45 3 16 COMPOSITION OF THE GAME BOARD...
Page 88: ...85 8 3 VCT 0520UK ASSY BILLBOARD DX...
Page 91: ...88 8 5 VCT 1000UK ASSY PTV CABI DX...
Page 113: ...LOCATE A3 SCHEMATIC DRAWING 1 HERE...
Page 114: ...LOCATE A3 SCHEMATIC DRAWING 2 HERE...