COIN HANDLING
59
12
Remove and clean smears by using a soft cloth dipped in water or diluted chemical detergent and then
squeezed dry.
Remove the CRADLE.. When removing the
retaining ring (E ring) be very careful so as not to
bend the rotary shaft.
Remove stain from the rotary shaft and shaft
receiving portions by wiping off with a soft cloth.
etc.
After wiping off as per previous step, further apply a dry cloth to completely dry the Coin Selector.
CLEANING THE COIN SELECTOR (MECHANICAL).
Once every month, when performing the Coin SW Test, simultaneously check the following:
Does the Coin Meter count satisfactorily?
Does the coin drop into the cashbox correctly?
Is the coin rejected when inserted while keeping the REJECT Button pressed down?
Coin Insertion Test
12-1 FIG 2
12-1 FIG 3
CRADLE
Insert a coin while keeping
the REJECT Button pressed
down and check if it is
rejected.
1
2
3
4