4
PRECAUTIONS REGARDING INST
ALLA
TION LOCA
TION
2
2
PRECAUTIONS REGARDING INSTALLATION
This product is an indoor game machine. Do not install it outside. Even indoors,
avoid installing in places mentioned below so as not to cause a fire, electric
shock, injury and/or malfunction.
Places subject to rain or water leakage, or places subject to high humidity in the
proximity of an indoor swimming pool and/or shower, etc.
Places subject to direct sunlight, or places subject to high temperatures in the
proximity of heating units, etc.
Places filled with inflammable gas or vicinity of highly inflammable/volatile
chemicals or hazardous matter.
Dusty places.
Sloped surfaces.
Places subject to any type of violent impact.
Vicinity of anti-disaster facilities such as fire exits and fire extinguishers.
Areas where the temperature exceeds the applicable temperature (ambient
temperature) range of 5 to 30 degrees centigrade.
LIMITATIONS OF USAGE
Be sure to check the Electrical Specifications. Ensure that this product
is compatible with the location's power supply, voltage, and frequency
requirements. A plate describing Electrical Specifications is attached to the
product. Non-compliance with the Electrical Specifications can cause a fire and
electric shock.
This product requires a breaker and earth mechanism as part of the location
facilities. Using the product without these can cause a fire and electric shock.
Ensure that the indoor wiring for the power supply is rated at 15 A or higher (AC
single phase 100 V ~ 120 V area), and 7 A or higher (AC 220 V ~ 240 V area). Non-
compliance with the Electrical Specifications can cause a fire and electric shock.
Be sure to use an independent power supply equipped with an earth leakage
breaker. Using a power supply without an earth leakage breaker can cause an
outbreak of fire if a power surge occurs.
Putting many loads on one electrical outlet can cause generation of heat and a
fire resulting from overload.
When using an extension cord, ensure that the cord is rated at 7A or higher (AC
100 V ~ 120 V area) and 3A or higher (AC 220 V ~ 240 V area). Using a cord rated
lower than the specified rating can cause a fire and electric shock.
Summary of Contents for Double Spin
Page 12: ...HANDLING PRECAUTIONS 3 1 ...
Page 28: ...ASSEMBLY AND INSTALLATION 19 6 5 Refit the BACK PANEL M6X25 SKT CAP BLK 8 ...
Page 73: ...64 COIN HANDLING 12 STERLING PRICE OF PLAY SETTINGS SW1 ...