background image

 
This function is more of a backup for catastrophic cartridge failure.  Sometimes when an ARP
cartridge becomes corrupted, it can be re-flashed and made usable again.  Or if there is an actual
hardware failure (damage), a new cartridge must be purchased.  In either case, a CD application
which runs on the Saturn, must be used to reflash the cartridge.  

An example of a Saturn CD application which can reflash the cartridge is ExCyber’s ARFLASH
utility.  This can be found on Rockin’-B All Stars compilation at “

http://www.rockin-b.de/saturn-

rb-all-stars.html

”.

Also, there is a utility that may be run using the DataLink called “Saturn Cartridge Firmware
Flash Utility”  This can be downloaded here: 

http://ppcenter.webou.net/devblog/article/48/saturn-

cartridge-firmware-flash-utility-small-update.html

This is a binary file (flasher.bin) that may be executed on the Saturn, using the DataLink's “Send
Homebrew Game” function.  This can be used to update your cartridge firmware.  This can also
be run from CD, if your cartridge is not functional.

Step5 – Troubleshooting

The DataLink software will attempt to communicate many times with the DataLink device before
giving up and displaying an error message box.  If you receive this communication error message,
the possible reasons could be:

The wrong COM port has been selected

A COM port number higher than 9 has been assigned

The USB cable is not plugged into both the PC and the DataLink device

The 25pin ribbon cable connector is not plugged into the PAR cartridge

The Saturn is not powered on

The PAR cartridge is not at it’s Main Menu screen

The PAR cartridge is not making good contact and must be re-inserted 

The PAR cartridge firmware is too old, and must be updated

There has now been a test mode added to the software.  It is under File...USB Test.  This will
allow the USB communication to be tested, between the PC and the DataLink.  The Saturn and
ARP cartridge are not required for this test, just plug the DataLink into the PC.

The following cartridge firmwares have been tested so far.  Any newer versions should be
compatible with the DataLink.  If your cartridge has an older version of firmware, it may need to
be updated to operate correctly with the DataLink.

EMS Action Replay Plus version 2.01 (or newer)

Pro Action Replay version 1.94 (or newer)

Gameshark-USA version 1.91 (or newer)

 Feel free to send any further questions/comments to: 

[email protected]

 

Page 8 of 8

Summary of Contents for DataLink

Page 1: ...ation the PC will have assigned a virtual com port to the DataLink device To see which com port is being used go to your PC s Device Manager Expand the Ports COM LPT directory Make a note of which com...

Page 2: ...he PC When shutting down first turn power OFF to the Saturn Next disconnect the USB cable from the DataLink Device Finally remove the 25pin ribbon connector from the cartridge Step4 Using the DataLink...

Page 3: ...the status of the data transfer Also while data transfer is occurring the LED indicator on the DataLink will be flashing rapidly Note To use this received gamesave file on an emulator you can do the...

Page 4: ...ame saves to the Saturn will overwrite the entire contents of the Saturn battery backed ram As the transfer is occurring the progress bar shows the status of the data transfer Also while data transfer...

Page 5: ...this option is selected by default If loading a game to a specific address use the H prefix to enter an address in Hex format There is a checkbox below the option buttons This box must be checked in...

Page 6: ...directory that the application is running from A text box is available for describing the version region of the BIOS file When the Begin BIOS Retrieval button is pressed the BIOS of the Saturn is save...

Page 7: ...e application is running from A text box is available for describing the contents firmware gamesaves codes of the DataFlash file When the Begin Data Retrieval button is pressed the DataFlash contents...

Page 8: ...imes with the DataLink device before giving up and displaying an error message box If you receive this communication error message the possible reasons could be The wrong COM port has been selected A...

Reviews: