[Table of Contents]
[Previous Page]
[Next Page]
TROUBLESHOOTING
WARNING!
In order to prevent an electric shock, be sure to turn power off before performing work and touching the
interior of the machine. Be careful so as not to damage wiring. Damaged wiring can cause an electric
shock or short circuit accident.
For troubleshooting, first check the connection of the wiring connectors.
REPLACEMENT AND ADJUSTMENT OF FUSES
WARNING!
Be sure to use fuses meeting the specified rating. Using fuses exceeding the specified rating can cause a
fire or electric shock.
As shown in the figures below, open the side door on the left hand side of the cabinet, and the fuse
appears in the positions shown.
PROBLEM
CAUSE
COUNTER MEASURE
When the main SW is turned ON, the
machine is not activated.
The cord is not plugged
in.
Firmly insert the plug into the outlet.
Incorrect power
source/voltage.
Make sure that the power supply
voltages are correct.
Primary or secondary
fuse blown.
First, remove the cause of overcurrent,
then replace the fuse.
Primary Fuse:
7A 250V Fast Blo
Secondary Fuse:
5A 250V Slo Blo
4A Slo Blo
4A Fast Blo
Page 1 of 1
Troubleshooting
7/12/2005
http://www.sauservice.com/manuals/Gunblade%20Folder/GB47.html