4
|
EZQ MODEL
COOLER LOCATION
Check the proposed cooler location to ensure it is structurally
capable of supporting the weight of the cooler. If the roof is
structurally inadequate, provide an alternate load bearing
structure.
The ideal location for the cooler is in a central position on the
roof (away from sleeping areas and where people spend most
of their time) so that the duct runs are of approximately the
same length. Carefully consider neighbouring residences and
noise levels when locating the cooler, if necessary talk to the
customer and the neighbour before carrying out the installation.
Always locate the cooler where it will receive adequate fresh air
and not in a recess where it may be starved for air or where the
air is polluted.
Ensure location is a minimum of:
•
3m (10’) from a solid fuel heater flue,
•
1.5m (5’) from a gas flue,
•
5m (17’) from a sewer vent, and
•
600mm (2’) from a wall.
The cooler must be mounted at least 3m (10’), preferably 5m
(17’), away from any TV antenna or antenna cables. Make sure
the cooler is not between the antenna and the transmission
tower that is providing the television signal to the home.
Allow adequate access to and around the cooler for
maintenance. Provision must be made for access to electricity,
water supplies and drains.
Note!
Do you need to discuss the installation of items like
safety anchor points with the customer?
EXQ/EXS MODELS
X
ILL1204-C
ILL1385-B
To separate the transition from the pallet cut off the front
tabs and the rear flap.
Note!
These two pieces of timber will form a height
gauge to ensure the finished cooler is correctly
positioned.
Keep the pallet to create a gauge for locating the
transition piece and dropper.
ILL1653-A
ILL1654-A
ILL1655-A
Remove the cooler from the transition by removing the
4 internal tab screws (2 at the front and 2 at the rear),
then releasing the 9 clips.
EZQ DISASSEMBLY
EZQ MODEL ONLY