SEELEY INTERNATIONAL - INSTALLATION MANUAL
|
13
ELECTRICAL CONNECTION
cont.
ILL1062-G
ILL1678-A
Lift the flexible cover on the Electronics Module. You will see
some plug points.
Connect the water sensor plug (D) and inlet solenoid plug (C)
as shown.
LEGEND
A - Control Cable
B - Speed Adjustment
C - Inlet Solenoid
D - Water Sensor
E - Drain Valve
F - Pump
G - Operation & Fault
code LED’s
Do not connect the pump cable yet.
IMPORTANT!
Ensure the cables cannot rest in the water
once the tank is filled and plugs are connected in the correct
orientation.
ILL1075-C
Route the drain valve cable as shown before connecting it
to the electronics module (E).
Now turn on the isolation switch and replace the pad frames
(except the front padframe to allow access).
ILL1076-E
ILL1229-D
INSTALLING THE FAN ASSEMBLY
Carry the Venturi/Fan assembly to the air cooler and fit it back
in place. It will only fit one way.
Note!
Ensure the steel restraint cable and motor cable are
secured against the side of the venturi by the sticker. Lower the
Venturi/Fan assembly into place, ensuring the cables sit in the
channel (B).
Check that the 2 clips are properly engaged and locate the
venturi into position.
IMPORTANT!
Make sure the venturi is correctly and
symmetrically located all the way around it’s cavity. Check this
by making sure the venturi sits inside the locating ridge all the
way around (C).
Ensure the motor cable is not caught under the bottom lip of the
venturi, by pulling the cable through fully.
Snare the motor cable into one of the brackets at the top of the
opening (A).
ILL1229-D