SEELEY INTERNATIONAL - INSTALLATION MANUAL
|
11
WATER CONNECTIONS
cont.
ILL993-B
ILL414-C
Connect the solenoid cable (supplied in the kit) to the Solenoid
Valve. Route the cable through the hole in the Transition. See
diagram. The other end will be connected later.
IMPORTANT!
Make sure the cable does not interfere with the
Weatherseal and that it will not be crushed by the Venturi/fan
assembly.
Clip the solenoid cover into place under the air cooler. Then
screw the flexible water hose (supplied in the kit) onto the
Solenoid Valve. Make sure the rubber washer seal is in place.
IMPORTANT!
Take care when connecting the flexible water
hose to the solenoid valve or the float valve adaptor. The
threads may become crossed and the connection will fail.
ILL970-C
Cooler Models
Plugs
TBA250
1 Plug in
TBA350
1 Plug in
TBA450
2 Plugs in
TBA550
2 Plugs in
WATER CONNECTIONS
cont.
BLEED FUNNEL ALTERNATIVE
The bleed funnel is a simplified alternative to the drain valve. It
also provides overflow and drain features.
Assemble the bleed funnel to the Water Tank as shown.
Make sure the o-rings are fitted correctly. Screw the nut tight by
hand!!
Attach the Drain Adaptor under the Bleed Funnel and attach a
pipe to carry the water to a suitable drain point.
Do not allow the water to run freely onto the roof - it will stain
the roof!!
The required rate of bleed will vary according to the water
quality. Set it to the minimum rate, as shown in the following
table.
If salt starts to build up on the Cooling Pads insert another plug.
Adjust the bleed rate until the salt build up is minimised. The
water management devices fitted will help control the effects of
poor quality water, but they cannot eliminate the problem.