Agility 3 User Manual
Page 47
Event Message
Description
Soak fail Z=xx
Zone XX has failed in the soak test
Special KP=y
Special alarm from the from wireless keypad Y
Spkr l.bat rsS=y
Speaker low battery restore from siren Y
* Spkr low bat S=y
Speaker low battery trouble from siren Y
Start exit P=y
Exit time started in partition Y
* Stay:P=y C=zz
Partition Y stay armed by user ZZ
* Stay: P=y KF=zz
Partition Y stay armed by remote control ZZ
* Tamper I/O Mdl.
Tamper alarm from I/O module
Tamper I/O Mdl.
Tamper alarm restored from I/O module
* Tamper Keypad=y
Tamper alarm from keypad ID=Y
Tamper rs Zn=xx
Tamper alarm restore on zone no. XX
Tamper rst KP=y
Keypad Y tamper restore
* Tamper Siren=y
Tamper alarm from wireless siren Y
* Tamper Zone=xx
Tamper alarm from zone no. XX
* Tech alarm Zn=xx
Alarm from zone XX defined as Technical
Tech rstr Zn=xx
Alarm restored from zone XX defined as Technical
Tmp rstr Siren=y
Tamper alarm restore from wireless siren Y
Unbyp Box+Bell
Box + Bell reinstated from bypass
Unbypass Zone=xx
Zone no. XX is reinstated from bypass
Unknown event
Unknown event alert
User login C=xx
User XX has entered into programming mode. User 99 represents
remote programming from the configuration software
* Water Alrm Zn=xx
Flood alarm from zone no. XX
Water rstr Zn=xx
Flood alarm restore on zone no. XX
Z=xx auto bad
Zone self-test failed, zone no. XX
Z=xx auto ok
Zone self-test OK, zone no. XX
Zn=xx Trouble
Zone trouble event from zone XX
Zn=xx Trouble OK
Zone trouble event restore from zone XX
* Event message display cannot be suppressed, as specified by EN50131-1-2006.
Summary of Contents for Agility 3
Page 1: ...User Manual 9313 1881 ...