Agility 3 User Manual
Page 46
Event Message
Description
* Ksw away:P=y
Partition Y is armed by key switch
* Ksw disarm:P=y
Partition Y is disarmed by key switch
L.bat rstr KF=yy
Low battery trouble restore from wireless remote control YY
L.Temp rst Zn=xx
Low temperature alert restored from zone XX defined as a
temperature detector
* Lost Zone=xx
Wireless zone lost, zone no. XX
Low Bat rs Z=xx
Low battery trouble restored from wireless zone no. XX
Low bat. Zn=xx
Low battery trouble from wireless zone no. XX
Low bat.KF=yy
Low battery trouble from wireless remote control XX
* Low Temp. Zn=xx
Low temperature alert from zone XX defined as a temperature
detector
Main:AC restore
AC power restore on main panel
Main: Battery rst
Low battery trouble restore from the main panel
Main: Low AC
Loss of AC power from the main panel
Main: Low battery
Low battery trouble from the main panel
* MS=y call error
Communication fail trouble to MS phone no. Y
* MS=y restore
Communication fail trouble restore to MS phone no. Y
* Msg Box Tamper
Tamper alarm from the Listen In message box unit
Msg Box Tmp Rst.
Tamper alarm restore from the Listen In message box unit
No Com IP card
Communication failure between the Agility and IP card
* No comm I/O Mdl.
Communication failure between the Agility and I/O module
* No comm Siren=y
Communication failure between the Agility and siren Y
* No comm. GSM
No communication between the GSM/GPRS Module and the Agility
* Phone fail
If the phone line is cut or the DC level is under 1V
Phone restore
Phone line trouble restore
* Police Keypad=y
Police (panic) alarm from wireless keypad Y
* Police KF=yy
Police (panic) alarm from remote control YY
PTM: Send Data
Load new parameters into the Agility from PTM accessory
* Radio l.bat S=y
Radio low battery trouble from siren Y
Radio l.bat rS=y
Radio low battery restore from siren Y
* Remote away:P=y
The system has been armed from the configuration software
* Remote program
The system has been programmed from the configuration software
* Remote stay:P=y
The system has been armed in STAY mode from the configuration
software
Restore Zone=xx
Alarm restore in zone no. XX
* RF Jamming
Wireless receiver jamming
Rmt disarm:P=y
Partition Y disarmed from the configuration software
* Siren=y Lost
Siren Y is regarded as lost following supervision test
Siren=y Lost Rst
The Agility received a signal from siren Y after it has been regarded
as lost
Summary of Contents for Agility 3