PROGRAMMING HINTS
Password
If the password is lost or forgotten it can be restored to the factory default
(12345). Remove the RK600e unit from the mounting plate, disconnect
power (unplug the connector from J1 or disconnect the DC power supply)
press and HOLD the reset switch (SW1, on the reader circuit board), restore
power, then release the switch. Note that this will also reset the latch timer
to one second and operating mode to active.
Adding the Same Transponder More Than Once
If you add the same Transponder to the system more than once, the Tran-
sponder ID will be deleted from the previous User Number position and
added to the newest User Number position.
Setting the Latch Timer
The latch timer controls the latch relay, which has two sets of contacts; one
for unlocking the door or gate, and one for bypassing an external alarm
system. The factory preset latch time is 1 second but it can be changed
to any value from 1-30 seconds. If the latch timer is set to 0 seconds, this
pulses the latch relay for 0.25 second, sufficient for most electric turnstiles.
The beeper and LED are always fixed at one second.
Setting the Operating Mode
Three operating modes are possible. For normal operation select Mode
1; to temporarily lock out all transponders, select Mode 2; to hold the door
open continuously select Mode 3.
BASIC OPERATION
To use a Key Tag with Radio Key
®
600E, simply hold your Radio Key
®
Tran-
sponder near the RK600e Unit or optional Auxiliary Reader. The RK600e
Unit or Auxiliary Reader generates an RF field, which causes the Key Tag
to transmit a unique Transponder ID Number back to the Auxiliary Reader
or RK600e Unit.
If the Transponder ID Number is stored in memory, the latch relay is activated,
unlocking the controlled door or gate and shunting any external alarms. A
green light and a beep indicates that access is granted.