Weekly switch timer
• Example of the programming of timer A or timer
Solicitor's office:
Solicitor
(= Administrator)
:
Not allocated to any timer, unlimited access
Staff:
Allocated to timer A
Time window 1:
Mo – Fr, 8-16 hours
Time window 2:
Fr, 7-7:59 hours
Time window 3:
Sa, 8-11 hours
Cleaners:
Allocated to timer B
Time window 1:
Mo – Fr, 8–10 hours
Time window 2:
Tu, 17-19 hours
Time window 3:
Fr, 14-16:59 hours
...............................................................................................................................................
If time windows are programmed overlapping, the command which was processed last of all
will determine the status of the lock. This allows for very flexible programming.
Example: Time window 1: Mo-Fr, 8-16 hours
Time window 2: Fr, 14:30 - 15 hours
The lock is open Mo-Th from 8-16 hours. On Friday it is only open from 8-15 hours, because
the lock switches to "closed" at 15 hours.
If for one particular time of day (e.g. 14 hours) ON and OFF times are programmed, the OFF
command has the higher priority and the lock will be closed.
10
No. 3 Days: SA
ON : HM 08:00
OFF: HM 11:00
<