L/LVDS_CLK-: LVDS Channel #0 differential Clock.
LVDS_DDC_DAT: DisplayID DDC Data line for LVDS flat Panel detection. Bidirectional signal, electrical level +3.3V_S with a 2k2
Ω
pull-up resistor.
LVDS_DDC_CLK: DisplayID DDC Clock line for LVDS flat Panel detection. Output signal, electrical level +3.3V_S with a 2k2
Ω
pull-up resistor.
Boards configured for embedded Display Port (eDP) interface, instead, will have the following signals:
e/eDP0_TX0-: embedded DP differential data pair #0.
e/eDP0_TX1-: embedded DP differential data pair #1.
e/eDP0_TX2-: embedded DP differential data pair #2.
e/eDP0_TX3-: embedded DP differential data pair #3.
e/eDP0_AUX-: embedded DP auxiliary channel differential data pair.
eDP_HPD: embedded DP Hot Plug Detect. +3.3V_S electrical level signal with 100k
Ω
pull-down resistor
In both configurations, the following signals are used to manage the backlight:
BKLT_EN: +5V_S electrical level Output, 10k
Ω
pull-up resistor, Backlight Enable signal. It can be used to turn On/Off the backlight
’
s lamps of connected displays.