SBC-992-pITX
SBC-992-pITX User Manual - Rev. First Edition: 1.0 - Last Edition: 2.0 - Author: S.B. - Reviewed by G.G Copyright © 2016 SECO S.r.l.
19
CAUTION: handling batteries incorrectly or replacing with not-approved devices may present a risk of fire or explosion.
2.3.3
RTC Battery
For the occurrences when the module is not powered with an external power supply, on board there is a cabled coin Lithium Battery to supply, with a 3V voltage,
the Real Time Clock embedded inside AMD G-Series SOC.
Battery used is a cabled CR2032-LD Lithium coin-cell battery, with a nominal capacity of 220mAh.
The battery is not rechargeable, and can be connected to the board using dedicated connector CN5 which is a 2-pin
p1.27 mm type MOLEX p/n 53398-0271 or equivalent, with pinout shown in the table on the left.
Mating connector: MOLEX 51021-0200 receptacle with MOLEX 50079-8000 female crimp terminals.
In case of exhaustion, the battery should only be replaced with devices of the same type. Always check the orientation before
inserting and make sure that they are aligned correctly and are not damaged or leaking.
Never allow the batteries to become short-circuited during handling.
Batteries supplied with SBC-992-pITX are compliant to requirements of European Directive 2006/66/EC regarding batteries and accumulators. When putting out of
order SBC-992-pITX, remove the batteries from the board in order to collect and dispose them according to the requirement of the same European Directive
above mentioned. Even when replacing the batteries, the disposal has to be made according to these requirements.
2.3.4
Power rails naming convention
In all the tables contained in this manual, Power rails are named with the following meaning:
_S: Switched voltages, i.e. power rails that are active only when the board is in ACPI
’
s S0 (Working) state. Examples: +3.3V_S, +5V_S.
_A: Always-on voltages, i.e. power rails that are active both in ACPI
’
s S0 (Working), S3 (Standby) and S5 (Soft Off) state. Examples: +5V_A, +3.3V_A.
_U: unswitched ACPI S3 voltages, i.e. power rails that are active both in ACPI
’
s S0 (Working) and S3 (Standby) state. Examples: +1.5V_U
Other suffixes are used for application specific power rails, which are derived from same voltage value of voltage switched rails, if it is not differently stated (for
example, +5V
HDMI
is derived from +5V_S, and so on).
Battery connector - CN5
Pin
Signal
1
V
RTC
2
GND