4.3.11
Console Redirection submenu
Menu Item
Options
Description
Console Serial Redirect
Enabled / Disabled
Enable or disable Console redirection. When enabled, all the submenus of the following paragraph will appear
Terminal Type
VT_100 / /
VT_UTF8 / PC_ANSI
Set Console Redirection terminal type
Baud rate
115200 / 57600 / 38400 /
19200 / 9600 / 4800 / 2400
/ 1200
Set Console Redirection baud rate
Data Bits
7 bits / 8 bits
Set Console Redirection data bits
Parity
None / Even / Odd
Set Console Redirection parity bits
Stop Bits
1 bit / 2 bits
Set Console Redirection stop bits
Flow Control
None
RTS/CTS
XON/XOFF
Set Console Redirection flow control type
Information Wait Time
0 Seconds / 2 Seconds / 5
Seconds / 10 Seconds / 30
Seconds
Set Console Redirection port information display time
C.R. After Post
Yes / No
Console Redirection continues to work even after Bios POST.
AutoRefresh
Enabled / Disabled
When this feature is enabled, the screen will auto refresh once after detecting the connection of a remote
terminal
FailSafeBaudRate
This feature will auto detect remote terminal baud rate and connect C.R serial device with detected baud rate
ACPI SPCR Table
Enabled / Disabled
Serial Port Console Redirection Table.
When this feature is enabled, the SPCR table will be add-into ACPI tables.
Serial Port 0 -
Addr
IRQy
Serial Port 1 -
Addr
IRQy
Serial Port 2 -
Addr
IRQy
Serial Port 3 -
Addr
IRQy
See following menu items
These voices will be available only when Console Serial Redirect is Enabled and if at least one LPC Super I/O
is present on the carrier board.
Depending on the SuperI/O(s) found on the carrier board, this item will show the serial ports that are available,
with their address and IRQ (assigned). For each port it will be possible to set the paramters shown in the
following lines
PortEnable
Enable / Disabled
Enable / Disable single serial Port x for the console redirection
UseGlobalSetting
Enable / Disaled
Use or not global settings for Serial Port x for the console Redirection