ELECTRONIC PANEL LRX 2145
Mono-phase electronic exchange, for the automation of swing-
doors with incorporated receiver.
- Mod.
LG 2145
: Without radio Receiver
- Mod.
( LRQ 2145 )
: 30,875 Mhz
- Mod.
( LR 2145 )
: 306 Mhz
- Mod.
( LRS 2145 / 330 )
: 330 Mhz
- Mod.
( LRS 2145 / 418 )
: 418 Mhz
- Mod.
LRS 2145
: 433,92 Mhz “narrow band”
( ) This product is designed only for countries in which this
use is allowed
TECHNICAL DATA:
- Power supply :
230 Vac 50-60Hz 20W max.
- Flashing light output:
230 Vac 500 W max.
- Motor output:
230 Vac 500 W max.
- Electric lock output:
12 Vac 12 W max.
- Aux. power output:
24 Vac 5 W max.
- Warning light output:
24 Vac 4 W max.
- Limit switch and BT controls:
24 Vcc
- Working temperature:
-20
÷
85 °C
- Radio receiver:
refer to type
- Op. transmitters :
12-18 Bit or Rolling Code
- TX max. codes in memory:
120 (CODE or CODE PED)
- Container dimensiond:
240x185x110 mm.
- Protection capability:
IP 65
TERMINAL BOARD CONNECTION:
CN1 : Terminal board
1 : Earth.
2 : Earth.
3 : Earth.
CN2 : Terminal board
1 : 230 Vac input.
2 : 230 Vac input.
3 : 230 Vac flash input.
4 : 230 Vac flash input.
5 : Opening 1 motor output.
6 : Common 1 motor output.
7 : Closing 1 motor output.
8 : Opening 2 motor output.
9 : Common 2 motor output.
10 : Closing 2 motor output.
CN3 : Terminal board
1 : Electric lock feed output 12 Vac 12 W.
2 : Electric lock feed output 12 Vac 12 W.
3 : 24 Vac 5 W service feed output.
4 : 24 Vac 5 W service feed output.
5 : Warning light output 24 Vac 4 W.
6 : Warning light output 24 Vac 4 W.
7 : Open-close push button input (NA).
8 : Single pedestrian push button input (NA).
9 : Common GND input.
10 : Input lockout (NC).
11 : Safety device input 1 (NC).
12 : Common GND input.
13 : Safety device input 2 (NC).
14 : Opening limit switch input (NC).
15 : Common GND input.
16 : Closing limit switch input (NC).
17 : Aerial earth input .
18 : Aerial hot pole input.
I
MPORTANT NOTICE FOR THE INSTALLER
−
In order to have proper functioning of the radio receiver,
in cases where two or more supply-stations are used, it
is advised to install them at a distance of at least 3
metres from each other.
−
The supply-station must not have any type of
sectioning mechanism from the electrical line 230 Vac;
it is therefore the responsibility of the installer to see the
installation of a sectioning device within the plant.
−
The fixing of the electricity supply cables and their
connection, must be guaranteed by means of the
assembly of the cable presses which are provided as
“optional”.
−
The input, which is labelled as normally closed (NC),
must be b ondedif not used!!
OPERATING CHARACTERISTICS:
Automatic operation:
By using either the radio control (led CODE on) or the low
tension button panel (PUL) to operate the gates, commands
will have the following effect:
The first command impulse activates the opening mechanism
until time expiry of the timing motor or until the gate is fully
opened, the second command impulse closes the gate, if a
command impulse is received before the activation of the limit
switch, the direction of movement of the mechanis m will be
reversed
whether engaged in opening or closing operations.
Step by step operation:
By using either the radio control (led CODE on) or the low
tension button panel (PUL) to operate the gates, commands
will have the following effect:
The first com mand impulse activates the opening mechanism
until time expiry of the timing motor or until the gate is fully
opened, the second command impulse closes the gate, if a
command impulse is received before the activation of the limit
switch, the direction of movement of the mechanism will be
halted
whether engaged in opening or closing operations.
Automatic closing:
The control board may be set up automatically to close the
gates.
The set-up procedure is described under the instruction for
setting the delay period.
Pedestrian access:
If selected (led PED\ANTA S is off), using the radio command
(led CODE PED is on) or the low tension button panel (PED)
to activate the lock will mean that the first command opens the
lock for 10 seconds and the centre waits for 10 seconds
before closing the lock.
Single wing :
If selected (led PED\ANTA S is on), using the radio command
(led CODE PED is on) and the low tension button panel (PED)
to activate the lock will mean that only motor 1 used with
regard to normal functioning.
Access block:
GB