less than a second, at the same time the Led will shut off and
the operation will be concluded.
15) DELAY IN WING OPENING:
(programmed wing delay 15
sec. max.)
The manufacturer furnishes the panel if chosen the
automation of 2 motors with a delay in wing opening equal to
3 seconds (del. MOTOR 2 ).
If a reprogramming of the delay is needed in relation to its
opening, it must be effected during close frame in the
following manner: take position on the SEL, task when the led
WING DELAY OP. is flashing, then press in continuous
manner the MODE task for as long as the time desired,
release the MODE task, at the same time the memorisation of
the delay will be determined and the Led DELAY WING OP.
will be fixed. If desired not to have a delay in wing opening,
take position on the Led DELAY WING OP. then press MODE
task for less than a second, at the same time the Led will shut
off and the operation will conclude.
16) DELAY IN WING CLOSING:
(programmed wing delay 15
sec. max.)
The manufacturer furnishes the panel if chosen the
automation of 2 motors with a delay in wing closing equal to 3
seconds (del. MOTOR 1 ).
If a reprogramming of the delay is needed in relation to its
closing, it must be effected during close frame in the following
manner: take position on the SEL, task when the led WING
DELAY CL. is flashing, then press in continuous manner the
MODE task for as long as the time desired, release the MODE
task, at the same time the memorisation of the delay will be
determined and the Led DELAY WING CL. will be fixed. If
desired not to have a delay in wing closing, take position on
the Led DELAY WING CL. then press MODE task for less than
a second, at the same time the Led will shut off and the
operation will conclude.
17) POWER:
Central feed,
Led POWER
on.
RESET :
If it
necessary to
reset the
program
board to its
default
values, that
is with no
memorised
data, press
both SEL
and MODE
buttons
continuously, all the
RED
LEDs will flash at once
DIAGNOSTIC :
In corrispondence to all input commands in low tension, the
centre uses Led signals for every input command to allow
rapid status control. Logic of function: a lit Led means input
closed, an unlit light means input open.
Rev. 1.2 del 27-01-03
D
ECLARATION OF
C
ONFORMITY
SEAV s.r.l.
declares that the products:
Electronic exchange
LG 2145 - LRS 2145
Conforms with all of the requirements laid out in the EC
directive number: 99/5 which are based on the following
standards
:
- EN 301 489-3 ;
- EN 300 220-3 ;
-
EN 60335-1.
The samples which have been tested meet the essential
requirements which have been specified above, on the
basis of the results of the tests
.