background image

less than a second, at the same time the Led will shut off and 
the operation will be concluded. 
 

15)  DELAY IN WING OPENING:

 (programmed wing delay 15 

sec. max.) 
The manufacturer furnishes the panel if chosen the 
automation of 2 motors with a delay in wing opening equal to 
3 seconds (del. MOTOR 2 ).  
If a reprogramming of the delay is needed in relation to its 
opening, it must be effected during close frame in the 
following manner: take position on the SEL, task when the led 
WING DELAY OP. is flashing, then press in continuous 
manner the MODE task for as long as the time desired, 
release the MODE task, at the same time the memorisation of 
the delay will be determined and the Led DELAY WING OP. 
will be fixed. If desired not to have a delay in wing opening, 
take position on the Led DELAY WING OP. then press MODE 
task for less than a second, at the same time the Led will shut 
off and the operation will conclude. 
 

 
 
 
 
 
 
 
 
 
16)  DELAY IN WING CLOSING:

 (programmed wing delay 15 

sec. max.) 
The manufacturer furnishes the panel if chosen the 
automation of 2 motors with a delay in wing closing equal to 3 
seconds (del. MOTOR 1 ).  
If a reprogramming of the delay is needed in relation to its 
closing, it must be effected during close frame in the following 
manner: take position on the SEL, task when the led WING 
DELAY CL. is flashing, then press in continuous manner the 
MODE task for as long as the time desired, release the MODE 
task, at the same time the memorisation of the delay will be 
determined and the Led DELAY WING CL. will be fixed. If 
desired not to have a delay in wing closing, take position on 
the Led DELAY WING CL. then press MODE task for less than 
a second, at the same time the Led will shut off and the 
operation will conclude. 

 
17) POWER: 

Central feed, 
Led POWER 
on. 

 
RESET : 

If it 
necessary to 
reset the 
program 
board to its 
default 
values, that 
is with no 
memorised 
data, press 
both SEL 
and MODE 
buttons 

continuously, all the 

RED 

LEDs will flash at once 

 

DIAGNOSTIC : 

In corrispondence to all input commands in low tension, the 
centre uses Led signals for every input command to allow 
rapid status control. Logic of function: a lit Led means input 
closed, an unlit light means input open. 
 
 

Rev. 1.2 del 27-01-03

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

D

ECLARATION OF 

C

ONFORMITY

 

SEAV s.r.l.

 declares that the products: 

Electronic exchange

 

LG 2145 - LRS 2145 

Conforms with all of the requirements laid out in the EC 

directive number: 99/5 which are based on the following 

standards

:

 

- EN 301 489-3 ; 
- EN 300 220-3 ; 

EN 60335-1.

 

The samples which have been tested meet the essential 

requirements which have been specified above, on the 

basis of the results of the tests

 

 

 

 
 
 
 

Summary of Contents for LRX 2145

Page 1: ...ny type of sectioning mechanism from the electrical line 230 Vac it is therefore the responsibility of the installer to see the installation of a sectioning device within the plant The fixing of the electricity supply cables and their connection must be guaranteed by means of the assembly of the cable presses which are provided as optional The input which is labelled as normally closed NC must be ...

Page 2: ... Enabled 9 RALLENTAM Disabled Enabled 10 SPUNTO INIZ Disabled Enabled 11 COLPO ARIETE Disabled Enabled 12 PRELAMP Disabled Enabled 13 T MOT Unlimited timing Programmed delay 14 T PAUSA No automatic close With automatic close 15 RIT ANTE AP No wing delay Programmed delay 16 RIT ANTE CH No wing delay Programmed delay 17 POWER Central ON Central OFF 1 1 2 MOTORS For installation the centre has 2 prei...

Page 3: ...ou have programmed the motors 10 INITIAL MOTOR PICK UP This function is used when a notable reduction in engine power from the electric clutch is needed However this means that the motor will not have sufficient power to start and the engine pick up helps the engine during this initial 3 second phase helping the engine to full power The engine pick up option is disabled in the default setting To a...

Page 4: ...ng close frame in the following manner take position on the SEL task when the led WING DELAY CL is flashing then press in continuous manner the MODE task for as long as the time desired release the MODE task at the same time the memorisation of the delay will be determined and the Led DELAY WING CL will be fixed If desired not to have a delay in wing closing take position on the Led DELAY WING CL ...

Reviews: