The centre allows for the connection of block buttons (NC).
The motor will stop at any stage of operation if used. Another
motor command will be accepted only when the access block
is disactivated, and in any case, will signal the start of the
closing phase with flashing lights for 5 seconds.
If not used, the terminals must be jumped.
Safety device 1 :
The control board allows for the connection and control of
Photocells, Tyre sensors (NC). The interruption is only
possible during the closing process provoking the inversion of
the motor. If not used the terminals must be jumped.
Safety device 2 :
The control board allows for the connection and control of
Photocells, Tyre sensors (NC). Interruption during the
opening process will lead to the momentary halting of the lock.
Once released the centre will continue the opening phase.
Interruption during the closing process will cause the
inversion of the motor. If not used the terminals must be
jumped.
Warning light :
The centre allows the connection of a 24V light to show the
state of the automation process. Light off automation closed,
access open, slow flashing motor open, fast flashing motor
closing.
Electronic clutch:
The control is equipped with an adjustable electronic clutch,
using Trimmer VR1. To adjust, move Trimmer VR1 until the
device moves, but can still be blocked by an obstacle (for
example, the test can be carried out by blocking the device
with the hands).
Functioning of the Flasher:
The panel board is powered by an output for the use of a
flasher 230 VAC. Its function is conditioned by the movement
of the motor, by the function of the inserted flasher and the
automatic closure that if inserted enables the flash even
during a pause.
TIMER functioning :
The centre allows a ti mer to be connected instead if the open-
close (PUL) button command.
For example: the timer can be set to open the gates at 8am
and to close at 6pm. During this period automatic closing and
flashing signals are disactivated.
PROGRAMMING:
SEL button:
selects the type of function to be memorised, the
selection is indicated by a flashing Led.
By repeatedly pressing the button it is possible to choose the
desired function. The selection will remain active for 10
seconds indicated by a flashing Led, if no other operations are
executed during this period, the control board will return to its
previous state.
MODE button:
programmes the information relative the type of
function previously selected with the SEL button.
Led Reference
Led off
Led on
1) 1-2 MOTORI
1 motor automated
2 Motors automated
2) AUT / P-P
Automatic
Step by step
3) CODE
No code
Code activated
4) CODE PED.
No code
Code activated
5) INB.CMD.AP
Disabled
Enabled
6) PED/ANTA S.
Pedestrian
Single wing
7) MANT. PRESS.
Disabled
Enabled
8) SERR. ON PED.
Disabled
Enabled
9) RALLENTAM.
Disabled
Enabled
10) SPUNTO INIZ.
Disabled
Enabled
11) COLPO ARIETE
Disabled
Enabled
12) PRELAMP.
Disabled
Enabled
13) T. MOT.
Unlimited timing
Programmed delay
14) T. PAUSA.
No automatic close
With automatic close
15) RIT. ANTE AP
No wing delay
Programmed delay
16) RIT. ANTE CH
No wing delay
Programmed delay
17) POWER
Central ON
Central OFF
1) 1 – 2 MOTORS:
For installation, the centre has 2 preinstalled configurations
for the automation of 1 or 2 motors.
The default configuration offers control of one motor (sliding
gate for example). If needed, predefined control of 2 motors is
set in the following way: set the SEL button on the 1-2
MOTORS flashing Led, then press MODE button, and Led 1 -2
MOTORS will remain lit and the operation will be completed.
Follow this procedure to return the previous setting.
2) Automatic\Step by step:
The centre in its default setting shows the automatic working
function set (Led AUT/P-P is off). To set the step by step
function (Led AUT/P-P is on): set the SEL button on the AUT/P-
P flashing Led, then press the MODE button. Led AUT/P-P will
remain lit. Repeat the operation to return to the previous
setting.
3) CODE:
(Radio control code)
The board allows the memorisation up to 120 radio
commands having different codes, which are either fixed or
rolling code.
Programming.
The transmission code is programmed in the following
manner: press the SEL button until the CODE led flashes,
immediately transmit the pre-selected code with the desired
remote control, in the moment in which the led CODE remains
accessible, the programming, will be complete
When all 120
codes have been stored in the memory all the Led lights will
flash, signalling that nothing else can be stored..
Programming through Radio command.
This procedure, consents to enable the programming, without
direct intervention of the SEL task on the panel, but executing
the operation at a distance, allows the programming of
transmission codes without the having to use the SEL button
on the central direct. The ability of programming is executed in
the following manner: send in a continuous manner for max.
10 seconds the codes of the radio command previously
memorised, at the same time the panel will enter into
programming mode as explained above.
Ability of programming through Radio command.
The panel is furnished by the builder with the radio command
disabled, if you wish to enable the function, proceed in the
following manner: the panel board is powered by an output of
230VAC, keeping the SELL task pressed, at the same time
you will obtain a brief flashing of all the Leeds and the
programming will be complete.
If you wish to disable the function previously enabled, repeat
the operation or follow the RESET procedure.
Cancellation.
All the transmission codes are cancelled in the following
manner: press the SEL button until the CODE led flashes,
then press the SET button and the CODE Led will be turned off
and the cancellation will be completed.