4) CODE PED:
(Radio control code Ped. / Anta S.)
The programming procedure is as above, simply use Led
Code PED
5) INB. CMD. AP:
(Interrupting commands during opening and
pauses, if set)
The option to interrupt commands during opening and
pauses, if inserted, is used when the automation is detected
by the loop detector. The centre, during the opening phase
and pauses, does not receive commands from the loop
detector at every crossing.
The central in its default setting, offers the interruption of
commands when the gate is opening and during the pause
period. To activate, proceed in the following way: set the SEL
button on the INB.CMD.AP flashing Led, then press the MODE
button and Led INB.CMD.AP will remain lit. Repeat the
process to return to the previous setting.
6) Pedestrian/Single wing:
The central’s default setting has pedestrian access enabled
(Led PED/ANTA S. is off). To set single wing opening (Led
PED/ANTA S. is on): use the SEL button to light the Led
PED/ANTA S., then press the MODE button. Led PED/ANTA S.
will remain lit. Repeat the process to return to the previous
setting.
7) MAINTAINING HYDRAULIC MOTOR PRESSURE :
This option is used to compensate for the loss of pressure
with time. The centre sends a the lock command to close for 2
seconds every 2 hours.
The option is disabled in the default configuration. To active it,
use the SEL button to light Led MANT. PRESS. Then press
MODE. Led MANT. PRESS. Will remain lit. Repeat the
operation to return to the previous setting.
8) Electric lock “ON” button:
The electric lock “on” button is used when available, for
example with a sliding door and a pedestrian door attached.
In this mode it is possible to open the gate or door through
with button commands.
The default setting is lock ON with button input disabled. To
enable it use the SEL button to light the Led SER. ON PED,
then press MODE. Led SER. ON PED with light. Repeat the
operation to return to the previous setting.
9) Slowing-down:
(Program. Slowing time 15 sec. max.)
The function slowing the motor is used for shutter gates to
prevent the gates coming together at too high a speed during
the opening and closing phases.
The centre will start to reduce the motor’s velocity for the set
slowing period.
During the closing phase, when the slowing-down is finished,
the centre sends a close signal to facilitate the electric locking.
If electric locking ON with pedestrian input is enabled the
ultimate closing signal will not be executed.
The slowing function is disabled when the centre is in its
default setting. To activate it, use the SEL button to select the
RALLENTAM Led, then press the MODE button for the desired
period. At this point the Led will light. TO disable to function
use the SEL button to select the RALLENTAM Led and press
MODE for less than one second. The Led will go out and the
operation will be be complete.
You are advised to program this setting after you have
programmed the motors.
10) INITIAL MOTOR PICK-UP :
This function is used when a notable reduction in engine
power from the electric clutch is needed. However, th is
means that the motor will not have sufficient power to start,
and the engine pick up helps the engine during this initial 3-
second phase, helping the engine to full power.
The engine pick-up option is disabled in the default setting. To
activate it, press the SEL button to select the Led SPUNTO,
then press MODE: the Led will remain lit. Repeat the
procedure to return to the previous setting.
11) HAMMER OPENING :
This function used with closing gates with closing gates with
an electric lock and helps th e unlocking of the gate during the
opening phase. Before starting the opening phase the unit
sends a closing signal for 2 seconds.
In the default setting this option is disabled. To enable it, use
the SEL button to light Led C.ARIETE, then press MODE. The
Led C.ARIETE will remain lit. Repeat the operation to return to
the original setting.
12) WARNING LIGHT :
This function is used when it is necessary to show in advance
that automated movement will begin.
Before the motor starts, the centre will always light the light for
3 seconds.
In the default setting this option is disabled. To enable it, use
the SEL button to light Led PRELAMP, then press MODE. The
Led PRELAMP will remain lit. Repeat the operation to return to
the original setting.
13) T. MOT:
(Programming motor work time, max. 4 mins)
The centre is supplied with a preset motor time of 30
seconds.
If it is necessary to reset the time you must close the units in
the following manner: use the SEL button to light Led TMOT.
Then keep the MODE button pressed. Motor1 will start the
opening phase, and at the desired point release the MODE
button. When Led TMOT flashes rapidly keep the MODE button
pressed. Motor 2 will start the opening phase. Release the
MODE button at the desired point. The work time of the 2
motors is now set: Led TMOT will remain lit and the centre will
return the motors to their original position. If the centre is
programmed for 1 motor, Led 1-2 MOTOR OFF, the
programmed work time for Motor2 will not be followed.
For infinite work time use the SEL button to light Led TMOT
then press the MODE button for less than 1 second. Led
TMOT will go out and the operation will be complete.
14) T. PAUSE:
(Maximum programmed automatic wing closing 4
minutes)
The manufacturer furnishes the board with an automatic
closure (pause time equal to 15 sec.). If a reprogramming of
the automatic closing time is needed, it must be effected in
closed frame in the following manner: press the SELL button
until the T. PAUSE led flashes, then press and hold down the
MODE button for a period equal to the desired pause interval
between closing and opening operations, at the expiry of the
desired time leave the MODE button, at the same time the
memorisation of automatic closing time will be determined
and the Led T. PAUSE will be lit.
If decided not to have the automatic closing, take position on
the flash of the Led T. PAUSE after press the MODE task for