4) CODE PED:

(Radio control code Ped. / Anta S.) 

The programming procedure is as above, simply use Led 
Code PED 
 

5) INB. CMD. AP: 

(Interrupting commands during opening and 

pauses, if set) 
The option to interrupt commands during opening and 
pauses, if inserted, is used when the automation is detected 
by the loop detector. The centre, during the opening phase 
and pauses, does not receive commands from the loop 
detector at every crossing. 
The central in its default setting, offers the interruption of 
commands when the gate is opening and during the pause 
period. To activate, proceed in the following way: set the SEL 
button on the INB.CMD.AP flashing Led, then press the MODE 
button and Led INB.CMD.AP will remain lit. Repeat the 
process to return to the previous setting. 

6) Pedestrian/Single wing:

 

The central’s default setting has pedestrian access enabled 
(Led PED/ANTA S. is off). To set single wing opening (Led 
PED/ANTA S. is on): use the SEL button to light the Led 
PED/ANTA S., then press the MODE button. Led PED/ANTA S. 
will remain lit. Repeat the process to return to the previous 
setting. 

 
7) MAINTAINING HYDRAULIC MOTOR PRESSURE : 

This option is used to compensate for the loss of pressure 
with time. The centre sends a the lock command to close for 2 
seconds every 2 hours. 
The option is disabled in the default configuration. To active it, 
use the SEL button to light Led MANT. PRESS. Then press 
MODE. Led MANT. PRESS. Will remain lit. Repeat the 
operation to return to the previous setting. 
 

8) Electric lock  “ON” button: 

The electric lock “on” button is used when available, for 
example with a sliding door and a pedestrian door attached. 
In this mode it is possible to open the gate or door through 
with button commands. 
The default setting is lock ON with button input disabled. To 
enable it use the  SEL button to light the Led SER. ON PED, 
then press MODE. Led SER. ON PED with light. Repeat the 
operation to return to the previous setting. 
 

9) Slowing-down:

 

(Program. Slowing time 15 sec. max.)

 

The function slowing the motor is used for shutter gates to  
prevent the gates coming together at too high a speed during 
the opening and closing phases. 
The centre will start to reduce the motor’s velocity for the set 
slowing period. 
During the closing phase, when the slowing-down is finished, 
the centre sends a close signal to facilitate the electric locking.  
If electric locking ON with pedestrian input is enabled the 
ultimate closing signal will not be executed. 
The slowing function is disabled when the centre is in its 
default setting. To activate it, use the SEL button to select the 
RALLENTAM Led, then press the MODE button for the desired 
period. At this point the Led will light. TO disable to function 
use the SEL button to select the RALLENTAM Led and press 
MODE for less than one second. The Led will go out and the 
operation will be be complete. 

You are advised to program this setting after you have 
programmed the motors. 

 
10) INITIAL MOTOR PICK-UP : 

This function is used when a notable reduction in engine 
power  from the electric clutch is needed. However, th is 
means that the motor will not have sufficient power to start, 
and the engine pick up helps the engine during this initial 3-
second phase, helping the engine to full power. 
The engine pick-up option is disabled in the default setting. To 
activate it, press the SEL button to select the Led SPUNTO, 
then press MODE: the Led will remain lit. Repeat the 
procedure to return to the previous setting. 
 

11) HAMMER OPENING : 

This function used with closing gates with closing gates with 
an electric lock  and helps th e unlocking of the gate during the 
opening phase. Before starting the opening phase the unit 
sends a closing signal for 2 seconds. 
In the default setting this option is disabled. To enable it, use 
the SEL button to light Led C.ARIETE, then press MODE. The 
Led C.ARIETE will remain lit. Repeat the operation to return to 
the original setting. 
 

 
 
 
12) WARNING LIGHT : 

This function is used when it is necessary to show in advance 
that automated movement will begin. 
Before the motor starts, the centre will always light the light for 
3 seconds. 
In the default setting this option is disabled. To enable it, use 
the SEL button to light Led PRELAMP, then press MODE. The 
Led PRELAMP will remain lit. Repeat the operation to return to 
the original setting. 
 

 
13) T. MOT:

 

(Programming motor work time, max. 4 mins) 

The centre is supplied with a preset motor time of 30 
seconds. 
If it is necessary to reset the time you must close the units in 
the following manner: use the SEL button to light Led TMOT. 
Then keep the MODE button pressed. Motor1 will start the 
opening phase, and at the desired point release the MODE 
button. When Led TMOT flashes rapidly keep the MODE button 
pressed. Motor 2 will start the opening phase. Release the 
MODE button at the desired point. The work time of  the 2 
motors is now set: Led TMOT will remain lit and the centre will 
return the motors to their original position. If the centre is 
programmed for 1 motor, Led 1-2 MOTOR OFF, the 
programmed work time for Motor2 will not be followed. 
For infinite work time use the SEL button to light Led TMOT 
then press the MODE button for less than 1 second. Led 
TMOT will go out and the operation will be complete. 

 
14)  T. PAUSE:

 

(Maximum programmed automatic wing closing 4 

minutes)

 

The manufacturer furnishes the board with an automatic 
closure (pause time equal to 15 sec.). If a reprogramming of 
the automatic closing time is needed, it must be effected in 
closed frame in the following manner: press the SELL button 
until the T. PAUSE led flashes,  then press and hold down the 
MODE button for a period equal to the desired pause interval 
between closing and opening operations, at the expiry of the 
desired time leave the MODE button, at the same time the 
memorisation of automatic closing time will be determined 
and the Led T. PAUSE will be lit. 
If decided not to have the automatic closing, take position on 
the flash of the Led T. PAUSE after press the MODE task for 

Summary of Contents for LRX 2145

Page 1: ...ny type of sectioning mechanism from the electrical line 230 Vac it is therefore the responsibility of the installer to see the installation of a sectioning device within the plant The fixing of the electricity supply cables and their connection must be guaranteed by means of the assembly of the cable presses which are provided as optional The input which is labelled as normally closed NC must be ...

Page 2: ... Enabled 9 RALLENTAM Disabled Enabled 10 SPUNTO INIZ Disabled Enabled 11 COLPO ARIETE Disabled Enabled 12 PRELAMP Disabled Enabled 13 T MOT Unlimited timing Programmed delay 14 T PAUSA No automatic close With automatic close 15 RIT ANTE AP No wing delay Programmed delay 16 RIT ANTE CH No wing delay Programmed delay 17 POWER Central ON Central OFF 1 1 2 MOTORS For installation the centre has 2 prei...

Page 3: ...ou have programmed the motors 10 INITIAL MOTOR PICK UP This function is used when a notable reduction in engine power from the electric clutch is needed However this means that the motor will not have sufficient power to start and the engine pick up helps the engine during this initial 3 second phase helping the engine to full power The engine pick up option is disabled in the default setting To a...

Page 4: ...ng close frame in the following manner take position on the SEL task when the led WING DELAY CL is flashing then press in continuous manner the MODE task for as long as the time desired release the MODE task at the same time the memorisation of the delay will be determined and the Led DELAY WING CL will be fixed If desired not to have a delay in wing closing take position on the Led DELAY WING CL ...

Reviews: