OPERATION

MAINTENANCE

PRIMING THE SHALLOW WELL PUMP

TO PREVENT DAMAGE TO INTERNAL PARTS, DO NOT
START MOTOR UNTIL PUMP HAS BEEN FILLED WITH
WATER.

1. Be sure pressure regulator located on pump body is open

at all times during priming and running. Turn counter-
clockwise all the way.

2. Remove priming plug. Fill pump with water. Replace

priming plug. If a priming tee and plug have been pro-
vided for a long horizontal run, be sure this line is filled
and the plug replaced, using pipe compound on plug
threads. See Figure 7, Page 7.

3. Start the pump and run for approximately thirty (30) sec-

onds. Stop pump, remove prime plug and refill with
water. Replace prime plug and gauge and restart pump.
Water will be pumped in a few minutes, the time de-
pending on the depth to water and length of horizontal
run. If pump does not prime, check for a possible leak on
the suction side of pump. Check to be sure suction lift –
distance from water level to pump – does not exceed
twenty (20) feet.

PRIMING THE DEEP WELL PUMP

TO PREVENT DAMAGE TO INTERNAL PARTS, DO NOT
START MOTOR UNTIL PUMP HAS BEEN FILLED WITH
WATER.

1. Remove the priming plug. Open pressure regulator (turn

counter-clockwise) located on the pump body. Fill pump
and piping with water and replace plug and tighten only
until it seals.

NOTICE:

For location of pressure regulator, see Installation

Diagrams on Pages 4 and 5.

2. Close the pressure regulator (turn clockwise).

3. Open several faucets in the house or near the tank to pre-

vent pressure build up in tank.

4. Start pump. Pressure should build up rapidly as the jet and

pump prime. Pressure will be in excess of 60 pounds. If
this fails to happen, repeat 2 and 3 above.

5. Once unit has primed on pressure has stabilized, slowly

open (turn counter-clockwise) the pressure regulator and
water will begin to be pumped into tank.

6. Continue to open pressure regulator until pressure falters

(becomes erratic). At this point, close (turn clockwise)
the pressure regulator slightly until pressure stabilizes.
Close faucets and allow pump to pressurize the tank and
shut off.

7. To insure pump is operating properly, alternately open

and close faucets in system. With faucets open, pressure
will drop until pressure switch starts pump; and with
faucets closed, pressure will build up until pressure
switch shuts off pump.

8. There are certain conditions of deep well operation

whereby the pressure regulator can be completely open
without any faltering of pressure and if so, pump should
be operated in this manner.

LUBRICATION

It is not necessary to lubricate the pump or its motor. The
motor has two ball bearings lubricated for life. The me-
chanical shaft seal in the pump is water lubricated and self-
adjusting.

DRAINING FOR WINTER

When the pump is to be disconnected from service, or is in
danger of freezing, it should be drained. The pump has a
drain cock which must be opened. Remove the priming
plug to vent the pump. Drain the pressure tank. Drain all pip-
ing to a point below the freeze line.

To drain an air volume control, remove AVC tubing and turn
(loosen) it 180° on the 1/4" pipe fitting in the tank. This will
permit any water remaining in the air volume control to
drain back into the tank.

DISASSEMBLY AND ASSEMBLY OF PUMP

The SEARS Hydroglass

®

pump is designed for ease in servic-

ing and maintenance.

1.

Disassemble pump as follows:

A. Disconnect power.

B. Drain pump by opening drain cock on bottom of

pump body and remove pressure switch tubing from
fitting on top of pump body. This will allow air to re-
place the water in the pump.

C. Remove clamp, Key No. 11, Page 16, which holds the

two pump halves together.

D. Remove pump base mounting bolts. Motor assembly and

back half of pump can now be pulled away from pump
front half. Carefully remove O-Ring and place in a clean
area. Inside of pump is now accessible for service.

2. Reassembly of pump.

A. With a clean cloth, wipe out all foreign material from

the large O-Ring groove on the pump back half. Also
wipe clean the large O-Ring and also the small O-Ring,
Key No. 6, Page 16 on the diffuser, Key No. 10, Page
16. This will insure a good tight seal.

B. Lubricate O-Rings with petroleum jelly for ease of as-

sembly. Place large O-Ring in groove.

C. Pump halves can now be slid together until they are

parallel and are as close together as possible.

D. BE SURE inside of clamp is clean. Place clamp on

pump halves and snug up. Alternately tighten clamp
screw and tap around outside of clamp with a plastic
mallet. This will insure proper seating of O-Ring and
clamp.

E. Assemble base mounting bolts. Reconnect pressure

switch tubing and tighten drain cock.

F. Reprime pump and turn on power.

11

Summary of Contents for CRAFTMAN PROFESSIONAL HYDROGLASS 390.2519

Page 1: ...tions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A PROFESSIONAL HYDROGLASS CONVERTIBLE DEEP WELL JET PUMP Safety Instructi...

Page 2: ...r r c ca au us se e d de ea at th h Ground pump before connecting to power supply H Ha az za ar rd do ou us s p pr re es ss su ur re e I In ns st ta al ll l p pr re es ss su ur re e r re el li ie ef f...

Page 3: ...ource is disconnected 7 Be sure your pump electrical circuit is properly grounded 8 Complete pump and piping system MUST be protected against below freezing temperature Failure to do so could cause se...

Page 4: ...1 1 4 PLASTIC PIPE CHECK VALVE AND STRAINER PLASTIC PIPE 1 1 PLASTIC PIPE PIPE ADAPTERS INSTALLATION DEEP WELL Figure 1 Captive Air Pressure Tank Installation Deep Well 1400 1194 JET WELL SEAL PLASTIC...

Page 5: ...5 Figure 3 Captive Air Pressure Tank Installation Shallow Well Figure 4 Standard Pressure Tank Installation Shallow Well INSTALLATION SHALLOW WELL...

Page 6: ...stance to the water level exceeds the suction lift of the pump Adjustment of the pressure regulator causes the right amount of water to be diverted back to the jet for the most efficient operation 1 L...

Page 7: ...lete in well This serves to double check for leaks in piping and foot valve and simplifies final priming of pump INSTALLING CASING ADAPTER Slide adapter on to well casing as far as it will go Tighten...

Page 8: ...er than the suction tapping of the pump Horizontal Offset Piping Sizes Shallow Well Jets 1 1 4 1 1 2 2 Up to 25 Ft 25 to 50 Ft 50 to 200 Ft Horizontal Offset Piping Sizes Deep Well Jets Up to 50 Ft 50...

Page 9: ...the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 Go t...

Page 10: ...asing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the power supply wires to the pressure switch as shown in Figure 10 Figure 10 Pr...

Page 11: ...ts pump and with faucets closed pressure will build up until pressure switch shuts off pump 8 There are certain conditions of deep well operation whereby the pressure regulator can be completely open...

Page 12: ...haft Motor is now separated from pump see Figure 11 6 Lay back half of pump large surface down on a flat clean surface and tap out ceramic seat Clean seal cavity from which seal was removed and clean...

Page 13: ...s not have to be dis connected 3 Withdraw jet assembly from well 4 Unscrew and remove the venturi Remove nozzle with a socket wrench if possible and clean If nozzle cannot be removed clean as explaine...

Page 14: ...A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with plastic pipe where possible otherwise with ne...

Page 15: ...y ys st te em m S St to oc ck k N No o M Mo od de el l N No o H HP P 5 5 1 10 0 1 15 5 2 20 0 3 30 0 4 40 0 5 50 0 6 60 0 7 70 0 8 80 0 9 90 0 Shallow 29650 3 39 90 0 2 25 51 19 9 3 4 10 9 10 4 8 6 7...

Page 16: ...1 2 x 9 x 1 4 7 U109 6A U109 6A Shaft Seal 8 J105 42PT J105 8PAN Impeller 9 J1 39P J1 40P Diffuser 10 U9 199 U9 199 O Ring Diffuser 1 7 8 x 1 5 8 x 1 8 11 C19 54SS C19 54SS Clamp Tank Body 12 L76 34P...

Page 17: ...9 6 Clamp 3 U9 201 O Ring Venturi 4 N32P 63 Venturi Use with Model 390 2522 4 N32P 72E Venturi Use with Model 390 2519 5 J34P 41 51 Nozzle Use with Model 390 2522 5 J34P 44 54 Nozzle Use with Model 39...

Page 18: ...29902 90 J32P 18 J34P 42 52 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 3 39 90 0 2 25 52 22 2 70 J32P 22 J34P 43 53 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 90 J32P 18 J34P 42 52 J40 2...

Page 19: ...asing Adapter 1 U30 282ZP U30 282ZP Machine Bolt 3 8 16 x 5 Lg 2 Req 2 J16 19ZZP J16 23ZZP Upper Flange 3 J21 19 J21 19 Seal Ring Drive Pipe 4 J21 18 J21 18 Seal Ring Suction Pipe 5 U30 277ZP U30 277Z...