background image

INSTALLATION

NOTICE:

Use Teflon tape supplied with the pump or Plasto-

Joint Stik1 for making all pipe-thread connections to the
pump itself. To avoid stress-cracking, do not use pipe joint
compounds on the pump.

1. Wrap male pipe threads being attached to pump with one

or two layers of Teflon tape. Cover entire threaded por-
tion of pipe.

2. Do not overtighten threaded fittings in the plastic pump.

Be sure you do not try to tighten joint past thread stop in
pump port!

3. If leaks occur, remove fittings, clean off old tape, rewrap

with one to two layers of tape and remake the connec-
tion. If joint still leaks, replace the fittings (fittings may be
undersized).

4. Be sure to support all piping connected to the System.

MAJOR COMPONENTS AND WHAT
THEY DO

Tank and Air Volume Control

The tank serves two functions. It provides a reservoir of
water, some of which can be drawn through the house fix-
ture before the pump must start, and it maintains a cushion
of air under pressure.

When Captive Air

®

Tanks are used, no air volume control is

necessary. This tank contains a permanent pre-charge of air.

When a Standard Tank is used, an air volume control adds
air to the tank when it is needed. See instructions included
with Air Volume Control for details on installation and op-
eration.

Pressure Switch

The pressure switch provides for automatic operation.

M

MO

OD

DE

EL

L  N

NO

O..

P

PU

UM

MP

P  S

ST

TA

AR

RT

TS

S  A

AT

T P

PU

UM

MP

P  S

ST

TO

OP

PS

S  A

AT

T

3

39

90

0..2

25

51

19

9

40 Pounds

60 Pounds

3

39

90

0..2

25

52

22

2

40 Pounds

60 Pounds

Impeller, Jet and Pressure Regulator

The impeller of the pump rotates with the motor shaft, caus-
ing the water to fly out from its rim by centrifugal force. The
rotation of the impeller creates a vacuum which “pulls” in
more water. Part of the water is diverted back to the jet
where it again passes through the nozzle and venturi – cre-
ating additional vacuum to draw in more water and deliver-
ing it at high pressure to the impeller.

In a 

deep well installation

, the jet assembly is submerged

in the well because the vertical distance to the water level
exceeds the suction lift of the pump.

Adjustment of the pressure regulator causes the right
amount of water to be diverted back to the jet for the most
efficient operation.

1

Lake Chemical Co., Chicago, Illinois

In a 

shallow well installation

, the jet assembly is attached

directly to the pump because the vacuum created will pull
water to the pump.

The pressure regulator may be used to restrict the flow of
water in a shallow well system if the SEARS convertible
pump produces more water than the well can produce.

DEEP WELL PUMP INSTALLATION
(Figures 1 & 2, Page 4)

In a deep well installation, the jet assembly is submerged in
the well because the vertical distance to the water level ex-
ceeds the suction lift of the pump. A single pipe system must
be used in 2" and 3" wells. A double pipe system must be
used in 4" or larger wells.

Follow instructions packed with jet package for proper noz-
zle and venturi combination for your pumping depth.

DOUBLE PIPE JET

When a double pipe jet is selected, 2 pipes are used in the
well. One is the suction pipe, and the other, the pressure
pipe. Plastic pipe is ideal for double pipe installations, due
to its light weight and easy installation.

Use 100 pound flexible plastic pipe on horizontal jet pumps.

TO INSTALL 4" DOUBLE PIPE JET

First, inspect jet to make sure no foreign matter has entered
the openings.

Be certain no foreign matter enters pipe openings while in-
stalling the unit.

Plastic Pipe Installations

1. Attach a foot valve (not furnished) to the jet with a short

nipple.

2. Before installing, be certain foot valve operates freely.

3. A special plastic pipe adapter is included with the jet

which screws into the 1-1/4" suction tapping over the
venturi.

4. Assemble a plastic pipe adapter (not furnished) into 1"

tapping in the jet body.

5. Use sufficient length of plastic pipe to place the jet 10-15

feet below the lowest drawdown water level. This is the
level to which the water in the well will drop while being
pumped continuously.

6. Tighten all hose clamps securely. A sanitary well seal is re-

quired on top of the well casing. Use steel nipples and el-
bows or specialized galvanized steel elbows to go through
the well seat. Use plastic pipe adapters where special el-
bows are not used.

6

Summary of Contents for CRAFTMAN PROFESSIONAL HYDROGLASS 390.2519

Page 1: ...tions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A PROFESSIONAL HYDROGLASS CONVERTIBLE DEEP WELL JET PUMP Safety Instructi...

Page 2: ...r r c ca au us se e d de ea at th h Ground pump before connecting to power supply H Ha az za ar rd do ou us s p pr re es ss su ur re e I In ns st ta al ll l p pr re es ss su ur re e r re el li ie ef f...

Page 3: ...ource is disconnected 7 Be sure your pump electrical circuit is properly grounded 8 Complete pump and piping system MUST be protected against below freezing temperature Failure to do so could cause se...

Page 4: ...1 1 4 PLASTIC PIPE CHECK VALVE AND STRAINER PLASTIC PIPE 1 1 PLASTIC PIPE PIPE ADAPTERS INSTALLATION DEEP WELL Figure 1 Captive Air Pressure Tank Installation Deep Well 1400 1194 JET WELL SEAL PLASTIC...

Page 5: ...5 Figure 3 Captive Air Pressure Tank Installation Shallow Well Figure 4 Standard Pressure Tank Installation Shallow Well INSTALLATION SHALLOW WELL...

Page 6: ...stance to the water level exceeds the suction lift of the pump Adjustment of the pressure regulator causes the right amount of water to be diverted back to the jet for the most efficient operation 1 L...

Page 7: ...lete in well This serves to double check for leaks in piping and foot valve and simplifies final priming of pump INSTALLING CASING ADAPTER Slide adapter on to well casing as far as it will go Tighten...

Page 8: ...er than the suction tapping of the pump Horizontal Offset Piping Sizes Shallow Well Jets 1 1 4 1 1 2 2 Up to 25 Ft 25 to 50 Ft 50 to 200 Ft Horizontal Offset Piping Sizes Deep Well Jets Up to 50 Ft 50...

Page 9: ...the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 Go t...

Page 10: ...asing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the power supply wires to the pressure switch as shown in Figure 10 Figure 10 Pr...

Page 11: ...ts pump and with faucets closed pressure will build up until pressure switch shuts off pump 8 There are certain conditions of deep well operation whereby the pressure regulator can be completely open...

Page 12: ...haft Motor is now separated from pump see Figure 11 6 Lay back half of pump large surface down on a flat clean surface and tap out ceramic seat Clean seal cavity from which seal was removed and clean...

Page 13: ...s not have to be dis connected 3 Withdraw jet assembly from well 4 Unscrew and remove the venturi Remove nozzle with a socket wrench if possible and clean If nozzle cannot be removed clean as explaine...

Page 14: ...A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with plastic pipe where possible otherwise with ne...

Page 15: ...y ys st te em m S St to oc ck k N No o M Mo od de el l N No o H HP P 5 5 1 10 0 1 15 5 2 20 0 3 30 0 4 40 0 5 50 0 6 60 0 7 70 0 8 80 0 9 90 0 Shallow 29650 3 39 90 0 2 25 51 19 9 3 4 10 9 10 4 8 6 7...

Page 16: ...1 2 x 9 x 1 4 7 U109 6A U109 6A Shaft Seal 8 J105 42PT J105 8PAN Impeller 9 J1 39P J1 40P Diffuser 10 U9 199 U9 199 O Ring Diffuser 1 7 8 x 1 5 8 x 1 8 11 C19 54SS C19 54SS Clamp Tank Body 12 L76 34P...

Page 17: ...9 6 Clamp 3 U9 201 O Ring Venturi 4 N32P 63 Venturi Use with Model 390 2522 4 N32P 72E Venturi Use with Model 390 2519 5 J34P 41 51 Nozzle Use with Model 390 2522 5 J34P 44 54 Nozzle Use with Model 39...

Page 18: ...29902 90 J32P 18 J34P 42 52 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 3 39 90 0 2 25 52 22 2 70 J32P 22 J34P 43 53 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 90 J32P 18 J34P 42 52 J40 2...

Page 19: ...asing Adapter 1 U30 282ZP U30 282ZP Machine Bolt 3 8 16 x 5 Lg 2 Req 2 J16 19ZZP J16 23ZZP Upper Flange 3 J21 19 J21 19 Seal Ring Drive Pipe 4 J21 18 J21 18 Seal Ring Suction Pipe 5 U30 277ZP U30 277Z...

Page 20: ...ssional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Ho...