background image

2

WARNING

This is the safety alert symbol. When you see this symbol
on your pump or in this manual, look for one of the fol-
lowing signal words and be alert to the potential for per-
sonal injury:

DANGER

warns about hazards that 

will 

cause serious per-

sonal injury, death or major property damage if ignored.

WARNING 

warns about hazards that 

will 

or 

can 

cause se-

rious personal injury, death or major property damage if ig-
nored.

CAUTION 

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The label 

NOTICE 

indicates special instructions which are

important but not related to hazards.

Carefully read and follow all safety instructions in
this manual and on pump.

Keep safety labels in good condition. 

Replace missing or damaged safety labels.

Electrical Safety

W

WA

AR

RN

NIIN

NG

G

Wire motor for correct
voltage. See “Electrical”
section of this manual
and motor nameplate.

Ground motor before
connecting to power
supply.

Meet National Elect-
rical Code and local
codes for all wiring.

Follow wiring instruc-
tions in this manual
when connecting mo-
tor to power lines.

W

WA

AR

RN

NIIN

NG

G

General Safety

H

Ha

az

za

arrd

do

ou

us

s  v

vo

olltta

ag

ge

e..

C

Ca

an

n  s

sh

ho

oc

ck

k,,  b

bu

urrn

n,,  o

orr

c

ca

au

us

se

e  d

de

ea

atth

h..

Ground pump before
connecting to power
supply.

H

Ha

az

za

arrd

do

ou

us

s  p

prre

es

ss

su

urre

e!!

IIn

ns

stta

allll  p

prre

es

ss

su

urre

e  rre

elliie

eff

v

va

allv

ve

e  iin

n  d

diis

sc

ch

ha

arrg

ge

e  p

piip

pe

e..

Release all pressure on
system before working on
any component.

Relief valve must be capable of passing full pump flow at
75 PSI.

Pump water only with this pump.

Periodically inspect pump and system components.

Wear safety glasses at all times when working on pumps.

Keep work area clean, uncluttered and properly lighted;
store properly all unused tools and equipment.

Keep visitors at a safe distance from the work areas.

Pump body may explode if used as a

booster pump unless relief valve capable of passing
full pump flow at 75 PSI (517 kPa) is installed.

Motor normally operates at high temperature

and will be too hot to touch. It is protected from heat dam-
age during operation by an automatic internal cutoff
switch. Before handling pump or motor, stop motor and
allow it to cool for 20 minutes.

Make workshops childproof; use padlocks and master
switches; remove starter keys.

General Safety

Do not allow pump, pressure tank, piping, or any other sys-
tem component containing water to freeze. Freezing may
damage system, leading to injury or flooding. Allowing
pump or system components to freeze will void warranty.

W

WA

AR

RN

NIIN

NG

G

READ AND FOLLOW SAFETY INSTRUCTIONS!

Summary of Contents for CRAFTMAN PROFESSIONAL HYDROGLASS 390.2519

Page 1: ...tions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A PROFESSIONAL HYDROGLASS CONVERTIBLE DEEP WELL JET PUMP Safety Instructi...

Page 2: ...r r c ca au us se e d de ea at th h Ground pump before connecting to power supply H Ha az za ar rd do ou us s p pr re es ss su ur re e I In ns st ta al ll l p pr re es ss su ur re e r re el li ie ef f...

Page 3: ...ource is disconnected 7 Be sure your pump electrical circuit is properly grounded 8 Complete pump and piping system MUST be protected against below freezing temperature Failure to do so could cause se...

Page 4: ...1 1 4 PLASTIC PIPE CHECK VALVE AND STRAINER PLASTIC PIPE 1 1 PLASTIC PIPE PIPE ADAPTERS INSTALLATION DEEP WELL Figure 1 Captive Air Pressure Tank Installation Deep Well 1400 1194 JET WELL SEAL PLASTIC...

Page 5: ...5 Figure 3 Captive Air Pressure Tank Installation Shallow Well Figure 4 Standard Pressure Tank Installation Shallow Well INSTALLATION SHALLOW WELL...

Page 6: ...stance to the water level exceeds the suction lift of the pump Adjustment of the pressure regulator causes the right amount of water to be diverted back to the jet for the most efficient operation 1 L...

Page 7: ...lete in well This serves to double check for leaks in piping and foot valve and simplifies final priming of pump INSTALLING CASING ADAPTER Slide adapter on to well casing as far as it will go Tighten...

Page 8: ...er than the suction tapping of the pump Horizontal Offset Piping Sizes Shallow Well Jets 1 1 4 1 1 2 2 Up to 25 Ft 25 to 50 Ft 50 to 200 Ft Horizontal Offset Piping Sizes Deep Well Jets Up to 50 Ft 50...

Page 9: ...the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 Go t...

Page 10: ...asing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the power supply wires to the pressure switch as shown in Figure 10 Figure 10 Pr...

Page 11: ...ts pump and with faucets closed pressure will build up until pressure switch shuts off pump 8 There are certain conditions of deep well operation whereby the pressure regulator can be completely open...

Page 12: ...haft Motor is now separated from pump see Figure 11 6 Lay back half of pump large surface down on a flat clean surface and tap out ceramic seat Clean seal cavity from which seal was removed and clean...

Page 13: ...s not have to be dis connected 3 Withdraw jet assembly from well 4 Unscrew and remove the venturi Remove nozzle with a socket wrench if possible and clean If nozzle cannot be removed clean as explaine...

Page 14: ...A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with plastic pipe where possible otherwise with ne...

Page 15: ...y ys st te em m S St to oc ck k N No o M Mo od de el l N No o H HP P 5 5 1 10 0 1 15 5 2 20 0 3 30 0 4 40 0 5 50 0 6 60 0 7 70 0 8 80 0 9 90 0 Shallow 29650 3 39 90 0 2 25 51 19 9 3 4 10 9 10 4 8 6 7...

Page 16: ...1 2 x 9 x 1 4 7 U109 6A U109 6A Shaft Seal 8 J105 42PT J105 8PAN Impeller 9 J1 39P J1 40P Diffuser 10 U9 199 U9 199 O Ring Diffuser 1 7 8 x 1 5 8 x 1 8 11 C19 54SS C19 54SS Clamp Tank Body 12 L76 34P...

Page 17: ...9 6 Clamp 3 U9 201 O Ring Venturi 4 N32P 63 Venturi Use with Model 390 2522 4 N32P 72E Venturi Use with Model 390 2519 5 J34P 41 51 Nozzle Use with Model 390 2522 5 J34P 44 54 Nozzle Use with Model 39...

Page 18: ...29902 90 J32P 18 J34P 42 52 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 3 39 90 0 2 25 52 22 2 70 J32P 22 J34P 43 53 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 90 J32P 18 J34P 42 52 J40 2...

Page 19: ...asing Adapter 1 U30 282ZP U30 282ZP Machine Bolt 3 8 16 x 5 Lg 2 Req 2 J16 19ZZP J16 23ZZP Upper Flange 3 J21 19 J21 19 Seal Ring Drive Pipe 4 J21 18 J21 18 Seal Ring Suction Pipe 5 U30 277ZP U30 277Z...

Page 20: ...ssional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Ho...