TROUBLESHOOTING CHART

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Motor will not run

1. Disconnect switch is off

1. Be sure switch is on

2. Fuse is blown

2. Replace fuse

3. Starting switch is defective

3. Replace starting switch

4. Wires at motor are loose, 

4. Refer to instructions on wiring. Check and tighten all wiring. 

disconnected, or wired incorrectly

5. Pressure switch contacts are dirty

5. Clean by sliding pieces of plain paper between contacts

Motor runs hot and  1. Motor is wired incorrectly

1. Refer to instructions on wiring

overload kicks off

2. Voltage is too low

2. Check with power company. Install heavier wiring if wire 

size is too small. See wiring instructions

3. Pump cycles too frequently

3. See section below on too frequent cycling

Motor runs but no

1. Pump in new installation did 

1. In new installation:

water is delivered

not pick up prime through: 
a. Improper priming 

a. Re-prime according to instructions

b. Air leaks

b.  Check all connections on suction line, air volume control, and jet

c. Leaking foot valve

c. Replace foot valve

2. Pump has lost prime through:

2. In installation already in use:

a. Air leaks

a. Check all connections on suction line, air volume control, 

jet and shaft seal

b. Water level below suction 

b. Lower suction line into water and re-prime. If receding water level 

of pump

in well exceeds suction lift, a deep well pump is needed

3. Jet or impeller is plugged

3. Clean jet or impeller according to instructions

4. Check valve or foot valve is stuck 

4. Replace check valve or foot valve

in closed position

5. Pipes are frozen

5. Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

6. Foot valve and/or strainer are 

6. Raise foot valve and/or strainer above well bottom

buried in sand or mud

Pump does not 

1. Water level in well is lower than 

1. A deep well jet pump may be needed (over 20 ft. to water)

deliver water to full

estimated

capacity (Also

2. Steel piping (if used) is corroded or 

2. Replace with plastic pipe where possible, otherwise with new steel pipe 

check point 3

limed, causing excess friction

immediately above)

3. Offset piping is too small in size

3. Use larger offset piping

Pump pumps water

1. Pressure switch is out of adjustment

1. Adjust or replace pressure switch

but does not shut 

or contacts are “frozen”

off

2. Faucets have been left open 

2. Close faucets

3. Jet or impeller is clogged

3. Clean jet or impeller

4. Water level in well is lower than

4. Check possibility of using a deep well jet pump

estimated

5. Motor is wired incorrectly

5. Refer to instructions on wiring

Pump cycles too 

1. Standard pressure tank is water- 

1. Drain tank to air volume control tapping. Check air volume control for

frequently

logged and has no air cushion

defects. Check for air leaks at any connection

2. Pipe leak 

2. Check connections

3. Faucets or valves are open

3. Close faucets or valves

4. Foot valve leaks

4. Replace foot valve

5. Pressure switch is out of adjustment

5. Replace pressure switch

6. Air charge too low in

6. Disconnect electrical power and open faucets until all pressure is 

Captive Air

®

Tank

relieved. Using automobile tire pressure gauge, check air pressure in tank

Models 390.2519 and 390.2522

at the valve stem located at top of tank. If air pressure is lower, pump air

require 40 pounds for

into tank from outside source until proper air pressure is reached. Check

proper operation

air valve for leaks, using soapy solution, and replace core if necessary.

Air spurts from

1. Pump is picking up prime

1. As soon as pump picks up prime, all air will be ejected

faucets

2. Leak in suction side of pump

2. Check suction piping

3. Well is gaseous 

3. Change installation as described in manual

4. Intermittent over-pumping of well

4.  Lower foot valve if possible, otherwise restrict discharge side of pump

Continued on Page 15

Summary of Contents for CRAFTMAN PROFESSIONAL HYDROGLASS 390.2519

Page 1: ...tions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A PROFESSIONAL HYDROGLASS CONVERTIBLE DEEP WELL JET PUMP Safety Instructi...

Page 2: ...r r c ca au us se e d de ea at th h Ground pump before connecting to power supply H Ha az za ar rd do ou us s p pr re es ss su ur re e I In ns st ta al ll l p pr re es ss su ur re e r re el li ie ef f...

Page 3: ...ource is disconnected 7 Be sure your pump electrical circuit is properly grounded 8 Complete pump and piping system MUST be protected against below freezing temperature Failure to do so could cause se...

Page 4: ...1 1 4 PLASTIC PIPE CHECK VALVE AND STRAINER PLASTIC PIPE 1 1 PLASTIC PIPE PIPE ADAPTERS INSTALLATION DEEP WELL Figure 1 Captive Air Pressure Tank Installation Deep Well 1400 1194 JET WELL SEAL PLASTIC...

Page 5: ...5 Figure 3 Captive Air Pressure Tank Installation Shallow Well Figure 4 Standard Pressure Tank Installation Shallow Well INSTALLATION SHALLOW WELL...

Page 6: ...stance to the water level exceeds the suction lift of the pump Adjustment of the pressure regulator causes the right amount of water to be diverted back to the jet for the most efficient operation 1 L...

Page 7: ...lete in well This serves to double check for leaks in piping and foot valve and simplifies final priming of pump INSTALLING CASING ADAPTER Slide adapter on to well casing as far as it will go Tighten...

Page 8: ...er than the suction tapping of the pump Horizontal Offset Piping Sizes Shallow Well Jets 1 1 4 1 1 2 2 Up to 25 Ft 25 to 50 Ft 50 to 200 Ft Horizontal Offset Piping Sizes Deep Well Jets Up to 50 Ft 50...

Page 9: ...the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 Go t...

Page 10: ...asing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the power supply wires to the pressure switch as shown in Figure 10 Figure 10 Pr...

Page 11: ...ts pump and with faucets closed pressure will build up until pressure switch shuts off pump 8 There are certain conditions of deep well operation whereby the pressure regulator can be completely open...

Page 12: ...haft Motor is now separated from pump see Figure 11 6 Lay back half of pump large surface down on a flat clean surface and tap out ceramic seat Clean seal cavity from which seal was removed and clean...

Page 13: ...s not have to be dis connected 3 Withdraw jet assembly from well 4 Unscrew and remove the venturi Remove nozzle with a socket wrench if possible and clean If nozzle cannot be removed clean as explaine...

Page 14: ...A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with plastic pipe where possible otherwise with ne...

Page 15: ...y ys st te em m S St to oc ck k N No o M Mo od de el l N No o H HP P 5 5 1 10 0 1 15 5 2 20 0 3 30 0 4 40 0 5 50 0 6 60 0 7 70 0 8 80 0 9 90 0 Shallow 29650 3 39 90 0 2 25 51 19 9 3 4 10 9 10 4 8 6 7...

Page 16: ...1 2 x 9 x 1 4 7 U109 6A U109 6A Shaft Seal 8 J105 42PT J105 8PAN Impeller 9 J1 39P J1 40P Diffuser 10 U9 199 U9 199 O Ring Diffuser 1 7 8 x 1 5 8 x 1 8 11 C19 54SS C19 54SS Clamp Tank Body 12 L76 34P...

Page 17: ...9 6 Clamp 3 U9 201 O Ring Venturi 4 N32P 63 Venturi Use with Model 390 2522 4 N32P 72E Venturi Use with Model 390 2519 5 J34P 41 51 Nozzle Use with Model 390 2522 5 J34P 44 54 Nozzle Use with Model 39...

Page 18: ...29902 90 J32P 18 J34P 42 52 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 3 39 90 0 2 25 52 22 2 70 J32P 22 J34P 43 53 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 90 J32P 18 J34P 42 52 J40 2...

Page 19: ...asing Adapter 1 U30 282ZP U30 282ZP Machine Bolt 3 8 16 x 5 Lg 2 Req 2 J16 19ZZP J16 23ZZP Upper Flange 3 J21 19 J21 19 Seal Ring Drive Pipe 4 J21 18 J21 18 Seal Ring Suction Pipe 5 U30 277ZP U30 277Z...

Page 20: ...ssional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Ho...

Reviews: