background image

INSTALLATION

STEEL PIPING INSTALLATIONS

When steel pipe is used to install the jet, be sure all pipes
are clean and the ends are reamed. Screw both 1-1/4” NPT
suction pipe and 1" NPT drive pipe directly into the jet body.
The special adapter nipple furnished with the jet is not used
on steel pipe installations, and should be discarded. Add suf-
ficient piping, using pipe thread compound on the joints
until proper depth is reached.

NOTICE: 

Pipe compound can damage plastic components

in pump. Use only Teflon tape or Plasto-Joint Stik

1

when con-

necting pipe to pump.

SINGLE PIPE JETS - 2" OR 3" WELLS

Before installing jet in well, it is necessary to soften jet
leathers by soaking in water for a minimum of one hour.

Single pipe jets must be installed with steel suction piping
in the well. Make sure all pipes are clean and ends are
reamed before lowering any piping into the well. Look
through pipe to make certain there are no obstructions.

During the process of lowering pipe into the well, always in-
stall coupling on top end of pipe and above clamp. This will
prevent accidental dropping of pipe into well.

Attach the jet to the first length of suction pipe 1-1/4" (NPT).
Use turned couplings (furnished) on 2" wells. Standard cou-
plings may be used for suction piping on 3" wells. Use pipe
compound on male threads only.

Tighten each length of pipe as it is lowered into the well.
Lower it to proper depth which is 10-15 feet below the
drawdown water level. This is the level to which the water
will drop while the well is being pumped continuously.

NOTICE:

Due to normal irregularities in the leather of the

cup seals and the inner walls of the drop pipe, 2" packer jets
do not form a perfect seal. In a dormant system, water will
leak back into well over time and pump will normally start
and cycle to maintain system pressure level.

PRIMING PIPE (OR PIPES) IN WELL

Fill piping in well with water as each length is added, or after
piping is complete in well. This serves to double check for
leaks in piping and foot valve, and simplifies final priming of
pump.

INSTALLING CASING ADAPTER

Slide adapter on to well casing as far as it will go. Tighten
three bolts to seal the adapter to the casing. Place a 1” nip-
ple of proper length in the drive pipe opening in the casing
adapter, and tighten top nuts. This will seal the glands on to
both suction and drive piping. Add elbows and flexible pipe
adapters for horizontal installations.

1

Lake Chemical Co., Chicago, Illinois.

SHALLOW WELL INSTALLATION 
AND OPERATION

Installing the Pump on a Shallow Well

A shallow well jet is available for use when the SEARS jet
pump is installed on wells 20 feet or less to drawdown water
level.

Install this jet as follows:

a. Loosen the stainless steel clamp until it fits over the flange

on the jet body.

b. Place O-Ring in circular groove on face of suction-drive

line flange. If necessary, use petroleum jelly to hold in
place.

c. Venturi that protrudes from the jet body must be inserted

in top (1-1/4" NPT) tapping. For ease of assembly, lubri-
cate the small O-Ring on the end of the venturi and push
the shallow well jet assembly into place.

d. Align lugs on jet body with slots in pump.

e. Place clamp over the flanges and tighten securely.

For standard tank installations, an air volume control is nec-
essary and is connected to the 1/8" tapping in the jet body.
Connect as shown in installation drawing, Figure 4, Page 5.

PIPING IN THE WELL

A shallow well jet pump can be installed on a dug well,
drilled well or with a driven point. SEARS shallow well jet
pumps have a built-in check valve. In a dug or cased well, a
foot valve and strainer is recommended and should be in-
stalled 5 to 10 feet below the lowest level to which the water
will drop while the pump is operating (pumping water
level). See Figure 4, Page 5. Your well driller can furnish this
information. The strainer should not be too close to the bot-
tom, or sediment may clog it. Before installing foot valve,
check to see if it works freely.

When using a foot valve, a priming tee and a plug as shown
in Figure 7 is recommended.

7

182 0893

Figure 7

Summary of Contents for CRAFTMAN PROFESSIONAL HYDROGLASS 390.2519

Page 1: ...tions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A PROFESSIONAL HYDROGLASS CONVERTIBLE DEEP WELL JET PUMP Safety Instructi...

Page 2: ...r r c ca au us se e d de ea at th h Ground pump before connecting to power supply H Ha az za ar rd do ou us s p pr re es ss su ur re e I In ns st ta al ll l p pr re es ss su ur re e r re el li ie ef f...

Page 3: ...ource is disconnected 7 Be sure your pump electrical circuit is properly grounded 8 Complete pump and piping system MUST be protected against below freezing temperature Failure to do so could cause se...

Page 4: ...1 1 4 PLASTIC PIPE CHECK VALVE AND STRAINER PLASTIC PIPE 1 1 PLASTIC PIPE PIPE ADAPTERS INSTALLATION DEEP WELL Figure 1 Captive Air Pressure Tank Installation Deep Well 1400 1194 JET WELL SEAL PLASTIC...

Page 5: ...5 Figure 3 Captive Air Pressure Tank Installation Shallow Well Figure 4 Standard Pressure Tank Installation Shallow Well INSTALLATION SHALLOW WELL...

Page 6: ...stance to the water level exceeds the suction lift of the pump Adjustment of the pressure regulator causes the right amount of water to be diverted back to the jet for the most efficient operation 1 L...

Page 7: ...lete in well This serves to double check for leaks in piping and foot valve and simplifies final priming of pump INSTALLING CASING ADAPTER Slide adapter on to well casing as far as it will go Tighten...

Page 8: ...er than the suction tapping of the pump Horizontal Offset Piping Sizes Shallow Well Jets 1 1 4 1 1 2 2 Up to 25 Ft 25 to 50 Ft 50 to 200 Ft Horizontal Offset Piping Sizes Deep Well Jets Up to 50 Ft 50...

Page 9: ...the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 Go t...

Page 10: ...asing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the power supply wires to the pressure switch as shown in Figure 10 Figure 10 Pr...

Page 11: ...ts pump and with faucets closed pressure will build up until pressure switch shuts off pump 8 There are certain conditions of deep well operation whereby the pressure regulator can be completely open...

Page 12: ...haft Motor is now separated from pump see Figure 11 6 Lay back half of pump large surface down on a flat clean surface and tap out ceramic seat Clean seal cavity from which seal was removed and clean...

Page 13: ...s not have to be dis connected 3 Withdraw jet assembly from well 4 Unscrew and remove the venturi Remove nozzle with a socket wrench if possible and clean If nozzle cannot be removed clean as explaine...

Page 14: ...A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with plastic pipe where possible otherwise with ne...

Page 15: ...y ys st te em m S St to oc ck k N No o M Mo od de el l N No o H HP P 5 5 1 10 0 1 15 5 2 20 0 3 30 0 4 40 0 5 50 0 6 60 0 7 70 0 8 80 0 9 90 0 Shallow 29650 3 39 90 0 2 25 51 19 9 3 4 10 9 10 4 8 6 7...

Page 16: ...1 2 x 9 x 1 4 7 U109 6A U109 6A Shaft Seal 8 J105 42PT J105 8PAN Impeller 9 J1 39P J1 40P Diffuser 10 U9 199 U9 199 O Ring Diffuser 1 7 8 x 1 5 8 x 1 8 11 C19 54SS C19 54SS Clamp Tank Body 12 L76 34P...

Page 17: ...9 6 Clamp 3 U9 201 O Ring Venturi 4 N32P 63 Venturi Use with Model 390 2522 4 N32P 72E Venturi Use with Model 390 2519 5 J34P 41 51 Nozzle Use with Model 390 2522 5 J34P 44 54 Nozzle Use with Model 39...

Page 18: ...29902 90 J32P 18 J34P 42 52 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 3 39 90 0 2 25 52 22 2 70 J32P 22 J34P 43 53 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 90 J32P 18 J34P 42 52 J40 2...

Page 19: ...asing Adapter 1 U30 282ZP U30 282ZP Machine Bolt 3 8 16 x 5 Lg 2 Req 2 J16 19ZZP J16 23ZZP Upper Flange 3 J21 19 J21 19 Seal Ring Drive Pipe 4 J21 18 J21 18 Seal Ring Suction Pipe 5 U30 277ZP U30 277Z...

Page 20: ...ssional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Ho...