background image

10

STEP 9: INSTALL THE MATTRESS 
RETAINER BRACKET

Align the open ends of the retainer bracket with the 
"loop" retainer anchors located at the foot of the 
adjustable base. Then, slide the retainer bracket into the 
anchors allowing the ends to glide into the loop. 

STEP 10: ASSEMBLE THE 
HEADBOARD BRACKET (OPTIONAL)

Using the remote control, raise the head section of the 
adjustable base to its full height. Locate the round panel 
under the head section of the bed. The second round 
panel is for the bed leg. 

 Position the inner headboard bracket underneath 
the first round panel. The bracket opening should be 
facedown under the bar. Insert the small screw fitted 
with a washer into the slot under the inner headboard 
bracket and through the round panel. Tighten the bolt 
using the Allen key wrench. 

Place the open side of the outer headboard bracket 
onto the exposed square tube of the inner headboard 
bracket. Insert the retainer bolt fitted with a washer 
through the outer headboard bracket and into the inner 
headboard bracket. Tighten the bolt using the Allen key 
wrench. Leave loose enough for adjusting. 

Repeat the steps to install the brackets on the other end 
of the head section of the adjustable base. 

When the headboard brackets are assembled, make sure 
there is a space of 1.5 inches (38.1 mm) to 2 inches (50.8 
mm) between the edge of the bed and the headboard 
brackets. 

Securely fasten the headboard bracket bolts (not 
included with your adjustable base) to the end of the 
headboard bracket assembly. If you need to adjust the 
headboard brackets, unscrew the bolts holding the 
outer headboard bracket and move them the necessary 
distance. Screw the bolts back and tighten securely.

Installation Guide

NOTE:
If the adjustable base is setup without a headboard, 
place your mattress on the bed surface. Installation 
is now complete. For owners who purchased the 
optional Headboard Bracket Kit, proceed to Step 10 
to install the headboard bracket on your adjustable 
base.

IMPORTANT!

FAILURE TO FOLLOW THE INSTALLATION STEPS AS 
THEY APPEAR IN THIS GUIDE COULD RESULT IN 
DAMAGE TO YOUR ADJUSTABLE BASE.

MAKE SURE TO POSITION THE BOTTOM OF THE 
HEADBOARD CROSS MEMBER NO MORE THAN 3 
INCHES (76.2 MM) BETWEEN THE HEADBOARD AND 
THE TOP OF THE MATTRESS.

Summary of Contents for Posturematic Adjustable Base Inspire

Page 1: ...Adjustable Base Inspire Model OWNER S MANUAL ...

Page 2: ......

Page 3: ...ce Codes Queen SAUSQ01QN King Single SAUSQ01KS Single XL SAUSQ01SXL Sealy Posturematic Adjustable Base Inspire Safety Precautions Parts List Installation Guide Remote Control Guide Special Functions Troubleshooting Warranty 15 17 14 11 8 6 4 ...

Page 4: ...duct repairs or part replacement on your adjustable base IN HOME USE ONLY This adjustable base is designed exclusively for in home use IMPORTANT SAFETY FEATURES Weight Fail Safe Feature In the case that an overload of weight is placed on the head or foot mechanism the control unit will automatically stop all functions The control unit will automatically resume all functions 30 seconds after excess...

Page 5: ...t For optimal performance entering and exiting the adjustable base with the bed in the flat or level position if recommended SMALL CHILDREN AND PETS WARNING Immediately dispose of packing materials as it can pose a smother risk to small children and pets Injury could occur also if children or pets are permitted to play on or under the bed Do not allow children to operate this bed without adult sup...

Page 6: ... in the parts list are included A REMOTE CONTROL 1 B MATTRESS RETAINER BRACKET 1 Queen bed sizes ship with 6 legs Part ships with Queen bed sizes only Part ships with Single XL bed sizes only E CENTER CONNECTION BRACKET 2 D AA BATTERIES 2 9V BATTERIES 2 C BED LEG 4 F SCREW 2 NUT 2 WRENCH 1 G BED LEG STRAP 1 ...

Page 7: ...ld separately A INNER HEADBOARD BRACKET 2 B OUTER HEADBOARD BRACKET 2 C SMALL SCREW 2 WASHER 2 D RETAINER BOLT 2 WASHER 2 E ALLEN KEY WRENCH 1 To order the Headboard Bracket Kit please contact Sealy Customer Care at 1300 130 221 ...

Page 8: ...head and foot sections of the adjustable base Using a wrench remove the screw and nut holding the brackets in place by turning them counter clockwise Remove the brackets to separate the head and foot sections of the bed To reconnect both sections align the bars and frames properly and then place the brackets back over the bars Make sure to line them up with the pre drilled holes Insert the screw t...

Page 9: ...ble frame STEP 5 Rotate the adjustable base carefully so the top side is now facing upward STEP 6 Plug the power cord into a working electrical outlet STEP 7 Install batteries in the remote control Try all functions on the remote to make sure all features are operational If the adjustable base does not work see the Troubleshooting section of this manual STEP 8 Return the adjustable base to a flat ...

Page 10: ...acket Tighten the bolt using the Allen key wrench Leave loose enough for adjusting Repeat the steps to install the brackets on the other end of the head section of the adjustable base When the headboard brackets are assembled make sure there is a space of 1 5 inches 38 1 mm to 2 inches 50 8 mm between the edge of the bed and the headboard brackets Securely fasten the headboard bracket bolts not in...

Page 11: ...ections of your adjustable base Flat 3 Press and hold this button to return the bed to a flat position Presets Anti Snore 4 Press this button to gently raise the head section and allow easier air intake which can help reduce snoring Reading TV 5 Press this button to raise the head section to an ideal position for watching TV reading or laptop use Zero G or Zero Gravity 8 Press this button to eleva...

Page 12: ...occur you MUST seek professional assistance to replace the fuse Call Sealy Customer Care at 1300 130 221 PAIRING YOUR REMOTE CONTROL TO YOUR ADJUSTABLE BASE w STEP 1 Plug your adjustable base to a working electrical outlet Using a surge protector is recommended The control box automatically enters and stays in pairing mode for seven 7 seconds STEP 2 On the remote control press the ZG and Foot Up b...

Page 13: ...ower cord from the electrical outlet STEP 2 Press and hold the FLAT button to continue sending a signal to the control box then plug the power cord back in STEP 3 After seven 7 seconds release the FLAT button STEP 4 Pair the remote control with its original control box Remote Control Guide NOTE To operate two adjustable bases simultaneously you must pair both beds Bed A and Bed B to one remote con...

Page 14: ...TEP 3 When the 9V batteries are installed and a power failure occurs press the FLAT button on the remote control for the bed to return to a flat position NOTE Your adjustable base supports the emergency power down feature when a power failure occurs while the head and or foot sections are raised NOTE The 9V batteries are for single use only After lowering the adjustable base once during a power fa...

Page 15: ...that the head section is not too close to the wall If a headboard is installed check that it is not too close to the edge of the mattress Make sure there is enough distance between the headboard bracket and the mattress HEAD OR FOOT LIFT FUNCTION HAS MINOR INTERFERENCE DURING OPERATION Check the batteries in the remote control Replace with new batteries if necessary Make sure that you are followin...

Page 16: ...ases together STEP 1 Complete the installation of two bases side by side It is recommended that the gap between adjustable bases be no more than 25mm STEP 2 Wrap the bed legs front and back together tightly using the bed leg straps STEP 3 Fasten the straps to prevent movement and maintain stability NOTE For safety reasons it is recommended that two people perform installation NOTE One bed leg stra...

Page 17: ...g the consumer about the unit for finding an unsatisfactory power connection and f if the recommended weight restrictions are not followed 386 kg on all sizes the warranty will be void Repairs to or replacement of the Sealy system or its components under the terms of this limited warranty will apply to the original warranty period and will not serve to extend such period The decision to repair or ...

Page 18: ...18 Notes ...

Page 19: ......

Page 20: ...TH YOUR BED AND ONLINE IF APPLICABLE IF PROBLEMS PERSIST PLEASE CALL CUSTOMER SERVICE NUMBER 1300 130 221 Please have your receipt ready and available THANK YOU AND ENJOY YOUR ADJUSTABLE BASE Model Number SEALY AU SPEC 25004 Reference Codes Queen SAUSQ01QN King Single SAUSQ01KS Single XL SAUSQ01SXL Serial Number 2019 Sealy of Australia ...

Reviews: