7.3.    

cleaning of the handle position and remote control storage area

7.4.    

remove the remote control from the storage area (fig 12). 

7.5.    

clean the handle position and remote control storage area with damp soft cloth only. 

do not

 allow water to drip into the unit. 

do

  

 

not

 soak the cleaning cloth.

8.  movinG the unit

8.5.1.   

to move the unit, hold the top of the air outlet on the front of the unit with one hand and the handle position at the top of the back of  

 

the unit with another hand, (fig 13). ensure that the unit remains upright. 

do not

 hold the horizontal louvre by hand.

8.5.2.   

leave the unit in the upright position when handling or moving it.

8.5.3. 

  

To handle or move the unit, drain the water in the unit first to prevent the water in the unit from flowing onto the ground or carpet.

8.5.4.   

if the remote control is in the position of the handle, take out the remote control, (fig 14).

9.  StoraGe

9.1.    

unscrew the drain cap, unplug the water plug and drain the water in the water tray to a suitable vessel.

 

note:

 

do not

 tilt the unit any further than 30° from vertical.

9.2.    

start the unit, adjust mode to the low fan speed setting, keep the unit in this state for half a day in order to dry the interior of the unit to  

 

prevent mould.

9.3.    

turn off the unit, unplug the power plug, wrap the power cord around the wire-winding post, insert the plug into the storage point on the  

 

rear of the unit; install the water plug and drain cap.

9.4.    

remove the exhaust hose assembly and store appropriately to prevent damage.

 

note:

 to remove the exhaust hose assembly, hold the handle of the exhaust hose retaining clamp, pull the retaining clamp outward

 

evenly, rotate the retaining clamp clockwise to open. remove the exhaust hose assembly.

9.5.    

Pack the air-conditioner in a soft plastic bag. store the unit in a dry and dust proof place. Keep the unit out of the reach of children.

9.6. 

  

remove batteries from the remote control. store remote control in an appropriate place.

9.7.    

ensure that the unit is stored in a dry place.

10.  troubleShootinG

 

Repairs should be carried out by suitably qualified persons only. 

fig.13

fig.14

s

AC9001 | Issue 3 (L) 29/11/16

Original Language Version

© Jack sealey limited

Summary of Contents for Sac9001

Page 1: ...appliance by the power cable 8 8 DO NOT pull the plug from the socket by the cable Remove the plug from the socket by maintaining a firm grip on the plug 8 8 DO NOT use worn or damaged cables plugs or connectors Ensure that any faulty item is repaired or replaced immediately by a qualified electrician 1 3 This product is fitted with a BS1363 A 13 Amp 3 pin plug If the cable or plug is damaged remo...

Page 2: ...e by children without supervision 2 introduction Thermostatically controlled unit with extendible exhaust hose and window kit ideal for home or office environments Features two speed fan and electronic remote control Air conditioning temperature range 17 30 C Also features a dehumidifying function capable of removing up to 24ltr day Refrigerant is R410A Mounted on castors for manoeuvrability Cable...

Page 3: ... shown in Fig 1 vertical or Fig 2 horizontal 4 5 Position the mobile air conditioner with the exhaust hose assembly attached near to a window Keep the mobile air conditioner at least 50cm away from the walls or other objects As shown in Fig 3 4 6 Snap the flat end of the exhaust hose connector into the elliptical hole of the window sealing board assembly as shown in Fig 4 and Fig 5 4 7 To ensure a...

Page 4: ...etting Temperature In this mode press Timer and Down button to set sleep function In sleep function after operating two hours the set temperature increases 1 C 1 F automatically After operating for another 2 hours the set temperature will increase 1 C 1 F again Then the set temperature will not change and the fan will switch to low level 5 3 2 Dehumidifying mode If the ambient temperature 17 C 62 ...

Page 5: ...e Dry button press this button to set this unit to operate in the dry mode Sleep mode press this button to set this unit to operate in the sleep mode 5 5 Antifreeze protection function Upon cooling when the compressor operates continuously for more than 10 minutes if the pipe temperature Tp is less than or equal to 2 C continuously for 20 seconds the compressor and water spraying motor turn off ot...

Page 6: ...er mesh are clogged with dust the function of the air conditioner may decrease 7 2 3 Remove the evaporator filter frame and the condenser filter frame gently in the direction shown by the arrow as shown in Fig 9 7 2 4 Remove the evaporator filter mesh and condenser filter mesh gently in the direction shown by the arrow as shown in Fig 10 7 2 5 Remove the filter frame first and then take out the fi...

Page 7: ... suitable vessel Note DO NOT tilt the unit any further than 30 from vertical 9 2 Start the unit adjust mode to the low fan speed setting keep the unit in this state for half a day in order to dry the interior of the unit to prevent mould 9 3 Turn off the unit unplug the power plug wrap the power cord around the wire winding post insert the plug into the storage point on the rear of the unit instal...

Page 8: ...completely unserviceable and requires disposal drain off any fluids if applicable into approved containers and dispose of the product and the fluids according to local regulations WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of ...

Reviews: