background image

 

8

  

do not

 connect or disconnect the plug from the mains with wet hands.

 

9

   Always discard the water from the collection tank, 

do not

 use it for any other purpose.

 

9

   Place the unit on a level and stable surface.

 

9

   to prevent water from freezing, do not use the unit at ambient temperatures below 0°c.

 

8

  

do not

 use the unit outside.

 

9

   Ensure that heating appliances are not exposed to the flow of air from the unit.

 

9

   Before attempting to move the unit, empty the contents of the water tank. see section 8 for instructions on moving.

 

9

   switch off and disconnect unit from the mains before attempting any cleaning or other maintenance work.

 

9

   ensure that the unit is turned off correctly when not in use, and stored in a safe, dry area, out of reach of children. see section 9.

 

note:

 this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or

 

mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of

 

the appliance in a safe way and understand the hazards involved. children shall not play with the appliance. cleaning and user

 

maintenance shall not be made by children without supervision.

2.  introduction

t

hermostatically controlled unit with extendible exhaust hose and window kit - ideal for home or office environments. Features two-speed

fan and electronic remote control. Air conditioning temperature range 17-30°c. Also features a dehumidifying function capable of removing

u

p to 24ltr/day. Refrigerant is R410A. Mounted on castors for manoeuvrability. Cable storage keeps unit tidy when not in use.

3.  Specification

model no:. . . . . . . . . . . . . . . . . . . . . . . . . . . . Sac9001

c

ooling Capacity: . . . . . . . . . . . . . . . . . . . . .9000Btu/hr

supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V

Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  999W

m

aximum Air Flow:. . . . . . . . . . . . . . . . . . . . .380mtr³/hr

m

aximum Water Extraction Rate:. . . . . . . . . . . 24ltr/day

refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . r410A

d

ischarge Side Pressure.. . . . . . . . . . . . . . . .   3.6MPa

suction side Pressure . . . . . . . . . . . . . . . . . . . 1.2mPa

exhaust Hose length. . . . . . . . . . . . . . . . . . . .1500mm

energy class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22kg

1. control panel.    

 

 

 

15. Air duct.

2. Horizontal louvre.  

 

 

 

16 Wire-winding posts.

3. Vertical louvre.    

 

 

 

17. drain cap.

4. Air outlet frame.   

 

 

 

18. Evaporator filter mesh.

5. Vertical Louvre connecting lever.  

 

 

19. Evaporator filter frame.

6. Caster.  

 

 

 

 

20. Radiating fine mesh.

7. Top cap.  

 

 

 

 

21. Condenser filter mesh.

8. Horizontal louvre connecting lever.    

 

22. Condenser filter frame.

9. main vertical louvre.  

 

 

 

23. Base plate.

10. front shell.  

 

 

 

 

24. Window sealing board assembly.

11. Handle / Remote Control Storage.   

 

25. Window sealing board.

12. Back shell.  

 

 

 

 

26. Exhaust Hose.

13. retaining clamp.  

 

 

 

27. connector.

14. Power cord.    

 

 

 

28. remote control.

s

AC9001 | Issue 3 (L) 29/11/16

Original Language Version

© Jack sealey limited

Summary of Contents for Sac9001

Page 1: ...appliance by the power cable 8 8 DO NOT pull the plug from the socket by the cable Remove the plug from the socket by maintaining a firm grip on the plug 8 8 DO NOT use worn or damaged cables plugs or connectors Ensure that any faulty item is repaired or replaced immediately by a qualified electrician 1 3 This product is fitted with a BS1363 A 13 Amp 3 pin plug If the cable or plug is damaged remo...

Page 2: ...e by children without supervision 2 introduction Thermostatically controlled unit with extendible exhaust hose and window kit ideal for home or office environments Features two speed fan and electronic remote control Air conditioning temperature range 17 30 C Also features a dehumidifying function capable of removing up to 24ltr day Refrigerant is R410A Mounted on castors for manoeuvrability Cable...

Page 3: ... shown in Fig 1 vertical or Fig 2 horizontal 4 5 Position the mobile air conditioner with the exhaust hose assembly attached near to a window Keep the mobile air conditioner at least 50cm away from the walls or other objects As shown in Fig 3 4 6 Snap the flat end of the exhaust hose connector into the elliptical hole of the window sealing board assembly as shown in Fig 4 and Fig 5 4 7 To ensure a...

Page 4: ...etting Temperature In this mode press Timer and Down button to set sleep function In sleep function after operating two hours the set temperature increases 1 C 1 F automatically After operating for another 2 hours the set temperature will increase 1 C 1 F again Then the set temperature will not change and the fan will switch to low level 5 3 2 Dehumidifying mode If the ambient temperature 17 C 62 ...

Page 5: ...e Dry button press this button to set this unit to operate in the dry mode Sleep mode press this button to set this unit to operate in the sleep mode 5 5 Antifreeze protection function Upon cooling when the compressor operates continuously for more than 10 minutes if the pipe temperature Tp is less than or equal to 2 C continuously for 20 seconds the compressor and water spraying motor turn off ot...

Page 6: ...er mesh are clogged with dust the function of the air conditioner may decrease 7 2 3 Remove the evaporator filter frame and the condenser filter frame gently in the direction shown by the arrow as shown in Fig 9 7 2 4 Remove the evaporator filter mesh and condenser filter mesh gently in the direction shown by the arrow as shown in Fig 10 7 2 5 Remove the filter frame first and then take out the fi...

Page 7: ... suitable vessel Note DO NOT tilt the unit any further than 30 from vertical 9 2 Start the unit adjust mode to the low fan speed setting keep the unit in this state for half a day in order to dry the interior of the unit to prevent mould 9 3 Turn off the unit unplug the power plug wrap the power cord around the wire winding post insert the plug into the storage point on the rear of the unit instal...

Page 8: ...completely unserviceable and requires disposal drain off any fluids if applicable into approved containers and dispose of the product and the fluids according to local regulations WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of ...

Reviews: